Publication 1756-UM522B-EN-P - February 2003
1756-DMF30 Specific Information C-57
1083
SL Buf Int Rx05
Displays the integer value of the Buffered Received Data for
word 5. Data transmitted from one node to another must be
the same data type. This parameter is paired with paramter
1084 [SL Buf Real Rx05].
Default:
Min:
Max:
Type:
File:
Group:
0
-2147483648
2147483648
Non-Linkable
Read-Only, 32-Bit Integer
SynchLink
Buffered Data In
1084
SL Buf Real Rx05
Displays the floating point (real) value of the Buffered
Received Data for word 5. Data transmitted from one node to
another must be the same data type. This parameter is paired
with paramter 1083 [SL Buf Int Rx05].
Default:
Min:
Max:
Type:
File:
Group:
0
-2200000000
2200000000
Non-Linkable
Read-Only, Floating Point
SynchLink
Buffered Data In
1085
SL Buf Int Rx06
Displays the integer value of the Buffered Received Data for
word 6. Data transmitted from one node to another must be
the same data type. This parameter is paired with paramter
1086 [SL Buf Real Rx06].
Default:
Min:
Max:
Type:
File:
Group:
0
-2147483648
2147483648
Non-Linkable
Read-Only, 32-Bit Integer
SynchLink
Buffered Data In
1086
SL Buf Real Rx06
Displays the floating point (real) value of the Buffered
Received Data for word 6. Data transmitted from one node to
another must be the same data type. This parameter is paired
with paramter 1085 [SL Buf Int Rx06].
Default:
Min:
Max:
Type:
File:
Group:
0
-2200000000
2200000000
Non-Linkable
Read-Only, Floating Point
SynchLink
Buffered Data In
1087
SL Buf Int Rx07
Displays the integer value of the Buffered Received Data for
word 7. Data transmitted from one node to another must be
the same data type. This parameter is paired with paramter
1088 [SL Buf Real Rx07].
Default:
Min:
Max:
Type:
File:
Group:
0
-2147483648
2147483648
Non-Linkable
Read-Only, 32-Bit Integer
SynchLink
Buffered Data In
1088
SL Buf Real Rx07
Displays the floating point (real) value of the Buffered
Received Data for word 7. Data transmitted from one node to
another must be the same data type. This parameter is paired
with paramter 1087 [SL Buf Int Rx07].
Default:
Min:
Max:
Type:
File:
Group:
0
-2200000000
2200000000
Non-Linkable, Read-Only, Floating Point
SynchLink
Buffered Data In
1089
SL Buf Int Rx08
Displays the integer value of the Buffered Received Data for
word 8. Data transmitted from one node to another must be
the same data type. This parameter is paired with paramter
1090 [SL Buf Real Rx08].
Default:
Min:
Max:
Type:
File:
Group:
0
-2147483648
2147483648
Non-Linkable, Read-Only, 32-Bit Integer
SynchLink
Buffered Data In
No.
Name
Description
Values
Содержание ControlLogix 1756-DMD30
Страница 1: ...ControlLogix Drive Module 1756 DMD30 1756 DMF30 User Manual y...
Страница 4: ......
Страница 8: ...Publication 1756 UM522B EN P February 2003 4...
Страница 10: ...Publication 1756 UM522B EN P February 2003 Summary of Changes 2 Notes...
Страница 14: ...Publication 1756 UM522B EN P February 2003 Preface 4 Notes...
Страница 26: ...Publication 1756 UM522B EN P February 2003 2 4 Drive Comm Drive Communication Notes...
Страница 44: ...Publication 1756 UM522B EN P February 2003 4 8 Installing the Drive Module Notes...
Страница 252: ...Publication 1756 UM522B EN P February 2003 B 172 1756 DMD30 Specific Information Notes...