Publication 1756-UM522B-EN-P - February 2003
1756-DMF30 Specific Information C-43
647
Real Out07
Displays output word 07 of the controller communication
format in floating point format. Paired with parameter 646
[Integer Out07], which displays the same data in integer
format.
Default:
Min:
Max:
Type:
File:
Group:
0
-2147483648
2147483648
Linkable, Read-Write, 32-Bit Integer
Communication
Logix Outputs
648
Integer Out08
Displays output word 08 of the controller communication
format in integer format. Paired with parameter 649 [Real
Out08], which displays the same data in floating point format.
Default:
Min:
Max:
Type:
File:
Group:
0
-2200000000
2200000000
Linkable, Read-Write, Floating Point
Communication
Logix Outputs
649
Real Out08
Displays output word 08 of the controller communication
format in floating point format. Paired with parameter 648
[Integer Out08], which displays the same data in integer
format.
Default:
Min:
Max:
Type:
File:
Group:
0
-2147483648
2147483648
Linkable, Read-Write, 32-Bit Integer
Communication
Logix Outputs
650
Integer Out09
Displays output word 09 of the controller communication
format in integer format. Paired with parameter 651 [Real
Out09], which displays the same data in floating point format.
Default:
Min:
Max:
Type:
File:
Group:
0
-2200000000
2200000000
Linkable, Read-Write, Floating Point
Communication
Logix Outputs
651
Real Out09
Displays output word 09 of the controller communication
format in floating point format. Paired with parameter 650
[Integer Out09], which displays the same data in integer
format.
Default:
Min:
Max:
Type:
File:
Group:
0
-2147483648
2147483648
Linkable, Read-Write, 32-Bit Integer
Communication
Logix Outputs
652
Integer Out10
Displays output word 10 of the controller communication
format in integer format. Paired with parameter 653 [Real
Out10], which displays the same data in floating point format.
Default:
Min:
Max:
Type:
File:
Group:
0
-2200000000
2200000000
Linkable, Read-Write, Floating Point
Communication
Logix Outputs
653
Real Out10
Displays output word 10 of the controller communication
format in floating point format. Paired with parameter 652
[Integer Out10], which displays the same data in integer
format.
Default:
Min:
Max:
Type:
File:
Group:
0
-2147483648
2147483648
Linkable, Read-Write, 32-Bit Integer
Communication
Logix Outputs
654
Integer Out11
Displays output word 11 of the controller communication
format in integer format. Paired with parameter 655 [Real
Out11], which displays the same data in floating point format.
Default:
Min:
Max:
Type:
File:
Group:
0
-2200000000
2200000000
Linkable, Read-Write, Floating Point
Communication
Logix Outputs
No.
Name
Description
Values
Содержание ControlLogix 1756-DMD30
Страница 1: ...ControlLogix Drive Module 1756 DMD30 1756 DMF30 User Manual y...
Страница 4: ......
Страница 8: ...Publication 1756 UM522B EN P February 2003 4...
Страница 10: ...Publication 1756 UM522B EN P February 2003 Summary of Changes 2 Notes...
Страница 14: ...Publication 1756 UM522B EN P February 2003 Preface 4 Notes...
Страница 26: ...Publication 1756 UM522B EN P February 2003 2 4 Drive Comm Drive Communication Notes...
Страница 44: ...Publication 1756 UM522B EN P February 2003 4 8 Installing the Drive Module Notes...
Страница 252: ...Publication 1756 UM522B EN P February 2003 B 172 1756 DMD30 Specific Information Notes...