Publication 1756-UM522B-EN-P - February 2003
B-56 1756-DMD30 Specific Information
186
PI Prop Gain
Controls the proportional gain of the Process Control regulator.
If the proportional gain is 1.0, the regulator output equals 1 pu
for 1 pu error.
Default:
Min:
Max:
Type:
File:
Group:
8
0
200
Linkable, Read-Write, Floating Point
Process Control
Regulator
187
PI Integ Time
Controls the integral gain of the Process Control regulator. If
the integrator time is 1.0, the regulator output equals 1 pu in 1
second for 1 pu error.
Units:
Default:
Min:
Max:
Type:
File:
Group:
/Sec
8
0
4095.8
Linkable, Read-Write, Floating Point
Process Control
Regulator
188
PI Integ HLim
The high limit of the integral gain channel for the Process
Control regulator. A value of 1 can represent either base motor
speed, motor rated torque, or 100% for some external
function.
Units:
Default:
Min:
Max:
Type:
File:
Group:
P.U.
0.1
0
8
Linkables Read-Write, Floating Point
Process Control
Regulator
189
PI Integ LLim
The low limit of the integral gain channel for the Process
Control regulator. A value of 1 can represent either base motor
speed, motor rated torque, or 100% for some external
function.
Units:
Default:
Min:
Max:
Type:
File:
Group:
P.U.
-0.1
-8
0
Linkable, Read-Write, Floating Point
Process Control
Regulator
190
PI Integ Output
Displays the output value of the integral channel of the
Process Control regulator. A value of 1 can represent either
base motor speed, motor rated torque, or 100% for some
external function.
Units:
Default:
Min:
Max:
Type:
File:
Group:
P.U.
0
-8
8
Non-Linkable, Read Only, Floating Point
Process Control
Regulator
191
PI High Limit
The high limit of the Process Control regulator output. A value
of 1 can represent either base motor speed, motor rated
torque, or 100% for some external function.
Units:
Default:
Min:
Max:
Type:
File:
Group:
P.U.
0.1
0
8
Linkable, Read-Write, Floating Point
Process Control
Regulator
192
PI Lower Limit
The low limit of the Process Control regulator output. A value
of 1 can represent either base motor speed, motor rated
torque, or 100% for some external function.
Units:
Default:
Min:
Max:
Type:
File:
Group:
P.U.
-0.1
-8
0
Linkable, Read-Write, Floating Point
Process Control
Regulator
No.
Name
Description
Values
Содержание ControlLogix 1756-DMD30
Страница 1: ...ControlLogix Drive Module 1756 DMD30 1756 DMF30 User Manual y...
Страница 4: ......
Страница 8: ...Publication 1756 UM522B EN P February 2003 4...
Страница 10: ...Publication 1756 UM522B EN P February 2003 Summary of Changes 2 Notes...
Страница 14: ...Publication 1756 UM522B EN P February 2003 Preface 4 Notes...
Страница 26: ...Publication 1756 UM522B EN P February 2003 2 4 Drive Comm Drive Communication Notes...
Страница 44: ...Publication 1756 UM522B EN P February 2003 4 8 Installing the Drive Module Notes...
Страница 252: ...Publication 1756 UM522B EN P February 2003 B 172 1756 DMD30 Specific Information Notes...