Publication 1756-UM522B-EN-P - February 2003
1756-DMF30 Specific Information C-79
2044
Rail Port 0 Flt
Indicates faults associated with Rail I/O on the port.
Default:
0000 0000 0000 0000
Options
Bit 0
Bit 1
Bit 2
Bit 3
Bit 4
Bit 5
Bit 6
Bit 7
Bit 8
Bit 9
Bti 10
Bit 11
Bit 12
Bit 13
Bit 14
Bit 15
Ch0 OvrRange
Ch0 UndRange
Ch1 OvrRange
Ch1 UndRange
Ch2 OvrRange
Ch2 UndRange
Ch3 OvrRange
Ch3 UndRange
Port NotCntd
Bad ID
Bad Chk Bits
I/O NotRdy
Reserved
Reserved
Reserved
Reserved
File:
Group:
DPS/PMI
Inputs & Outputs
2045
RailPrt 0FltCnt
Displays number of fault occurences at the port. Refer to
section 3.1, “Rail I/O Port Registers”, of Reliance Electric
publication 3036,
Distributed Power System SF3000 Drive
Configuration and Programming
.
Default:
Min:
Max:
Type:
File:
Group:
0
0
65535
Non-Linkable, Read-Only, 16-Bit Integer
DPS/PMI
Inputs & Outputs
2046
Rail Port 1 Ch 0
Enter the code for the type of Rail I/O on each channel. Refer
to section 3.1, “Rail I/O Port Registers”, of Reliance Electric
publication 3036,
Distributed Power System SF3000 Drive
Configuration and Programming
.
Default:
Min:
Max:
Type:
File:
Group:
0
0
65535
Linkable, Read-Write, 16-Bit Integer
DPS/PMI
Inputs & Outputs
2047
Rail Port 1 Ch 1
Enter the code for the type of Rail I/O on each channel. Refer
to section 3.1, “Rail I/O Port Registers”, of Reliance Electric
publication 3036,
Distributed Power System SF3000 Drive
Configuration and Programming
.
Default:
Min:
Max:
Type:
File:
Group:
0
0
65535
Linkable, Read-Write, 16-Bit Integer
DPS/PMI
Inputs & Outputs
2048
Rail Port 1 Ch 2
Enter the code for the type of Rail I/O on each channel. Refer
to section 3.1, “Rail I/O Port Registers”, of Reliance Electric
publication 3036,
Distributed Power System SF3000 Drive
Configuration and Programming
.
Default:
Min:
Max:
Type:
File:
Group:
0
0
65535
Linkable, Read-Write, 16-Bit Integer
DPS/PMI
Inputs & Outputs
2049
Rail Port 1 Ch 3
Enter the code for the type of Rail I/O on each channel. Refer
to section 3.1, “Rail I/O Port Registers”, of Reliance Electric
publication 3036,
Distributed Power System SF3000 Drive
Configuration and Programming
.
Default:
Min:
Max:
Type:
File:
Group:
0
0
65535
Linkable, Read-Write, 16-Bit Integer
DPS/PMI
Inputs & Outputs
No.
Name
Description
Values
Содержание ControlLogix 1756-DMD30
Страница 1: ...ControlLogix Drive Module 1756 DMD30 1756 DMF30 User Manual y...
Страница 4: ......
Страница 8: ...Publication 1756 UM522B EN P February 2003 4...
Страница 10: ...Publication 1756 UM522B EN P February 2003 Summary of Changes 2 Notes...
Страница 14: ...Publication 1756 UM522B EN P February 2003 Preface 4 Notes...
Страница 26: ...Publication 1756 UM522B EN P February 2003 2 4 Drive Comm Drive Communication Notes...
Страница 44: ...Publication 1756 UM522B EN P February 2003 4 8 Installing the Drive Module Notes...
Страница 252: ...Publication 1756 UM522B EN P February 2003 B 172 1756 DMD30 Specific Information Notes...