5 Maintenance
Ensure totally clean surfaces during mounting. Always use original Alfa Laval parts.
5.1
General Maintenance
-
Maintenance of the Agitator should only be performed by authorized personnel.
-
For maintenance instructions of gear motor please see 8.5 “Drive Unit Instruction”.
-
Ensure totally clean surfaces during maintenance.
-
For lifting instruction, please see 3 Installation.
-
Always disconnect the power supply when servicing the Agitator.
-
Always use proper tools.
-
Always replace worn sealing elements before reassembling.
-
Follow the dismantling and assembly instructions to the letter.
-
All scrap must be stored/disposed of in accordance with current rules and directives.
-
Always use original Alfa Laval spare parts.
Part
Replace every
Sealing
3000 hours or 2
nd
year
Bearing for bottom console (pos. 25)
3000 hours or 2
nd
year
5.2
Disassembling of agitator
Follow 3.4.2 - 3.4.6 in reverse order.
5.3
Replacement of gear motor
See 3.4.6.
5.4
Replacement of seals
See 3.4.3 - 3.4.5.
5.5
Replacement of Bearing for bottom console
The complete agitator must be lifted using a hoist and the bearing for bottom console pos. 25 can be changed.
22
Содержание ALTB-SB-20
Страница 1: ...ESE03056 EN6 2020 05 Original manual Instruction Manual ALTB SB 20...
Страница 2: ......
Страница 40: ...7 Parts list Service kits Ensure totally clean surfaces during mounting Always use original Alfa Laval parts 40...
Страница 43: ...8 Appendix Ensure totally clean surfaces during mounting Always use original Alfa Laval parts 8 3 WPS 43...
Страница 73: ...73...