VCore
Page 124
Digital Inputs
Input Connector
The VCore has 4 inputs that can control the show operation
Two forms of inputs can be applied to Inputs connector: Voltage Inputs, and Contact Closures.
When a specific input on the VCore is software configured for Voltage Inputs, power for the
connection is provided by an external source (in-rack power supply etc.), but when the input is
configured as a Contact Closure, power is taken internally from the VCore.
The
DIP switch position 2
determines Contact Closure or Voltage Mode.
For the pros and cons of each, see the section titled "Voltage Inputs vs. Contact Closures" in the
V16Pro section of this manual.
Input Configuration
The input names are configured by WinScript Live software. Select Resources command from the
main menu bar, and then select Inputs. Notice the input name may be changed, and a comment
describing the input’s use may be added. This makes it easier to remember what you were trying
to do when you look at the script again later!