V16Pro
Page 106
Digital Outputs
Configuring Outputs
The V16Pro provides 16 Dry-Contact Relay Outputs for discrete control. The initial state of each output
may be configured by WinScript Live to be open or closed when the script is started.
The back panel outputs are configured by WinScript Live software. Select Resources command from the
main menu bar then select Outputs. The window shown below opens. You may change the name, define
the initial state of the output, and add a comment to describe the output’s use.
Figure 6 - Outputs View
Output Connector
Note
The Relay Outputs are fused at 900mA using self-restoring polymer fuses. If an
overload occurs, the fuse will open until the problem is corrected; then it will heal itself.
Pin
Connection
Pin
Connection
1
Output 1
20
Output 1 Return
2
Output 2
21
Output 2 Return
3
Output 3
22
Output 3 Return
4
Output 4
23
Output 4 Return
5
Output 5
24
Output 5 Return
6
Output 6
25
Output 6 Return
7
Output 7
26
Output 7 Return
8
Output 8
27
Output 8 Return
9
Output 9
28
Output 9 Return
10
Output 10
29
Output 10 Return
11
Output 11
30
Output 11 Return
12
Output 12
31
Output 12 Return
Содержание V16Pro
Страница 1: ...V Series Network Controllers Alcorn McBride January 3 2018 User s Guide...
Страница 48: ......
Страница 64: ......
Страница 86: ......
Страница 91: ...V16Pro Page 91 V16Pro...
Страница 114: ......
Страница 118: ...VCore Page 118 VCore Figure 11 Front View Figure 12 Rear View...
Страница 119: ...VCore Page 119 VCore Figure 13 Top View Figure 14 Bottom View...
Страница 138: ......
Страница 167: ...Serial and Ethernet Control Page 167 Control Example Send Command AHJ 0D enables port A Response R 0D...
Страница 172: ......