![Alcorn Mcbride V16Pro Скачать руководство пользователя страница 47](http://html1.mh-extra.com/html/alcorn-mcbride/v16pro/v16pro_user-manual_2892710047.webp)
WinScript Live Timecode (SMPTE/EBU)
Page 47
W
inS
cr
ipt
A good level for this is usually 3-5 frames. If the timecode skips ahead (or behind) a number that is
less
than the tolerance, the sequence will continue to execute all events normally. If the timecode skips ahead
(or behind) a number of frames that is
more
than the tolerance, a “dropout” will be registered and the
sequence will either jump ahead (jam-sync mode) or reset (reset mode). For more information on
configuring an individual sequence’s clock, see Sequence Clock on page 14.
Generate Settings
•
Preroll Time
: Occurs once, on initial start, before reaching the “Start Time.” Any further loop
will go back to the Start Time.
•
Start Time:
The initial running time
•
End Time:
The time that the timecode stops or loops
•
Loop at End Time:
Returns to Start Time when End Time is reached
•
SMPTE Muted When Paused or Stopped:
No SMPTE time signal is generated on LTC output
when Paused or Stopped.
•
SMPTE Level:
The output level of the SMPTE/EBU signal in dbVp-p
Содержание V16Pro
Страница 1: ...V Series Network Controllers Alcorn McBride January 3 2018 User s Guide...
Страница 48: ......
Страница 64: ......
Страница 86: ......
Страница 91: ...V16Pro Page 91 V16Pro...
Страница 114: ......
Страница 118: ...VCore Page 118 VCore Figure 11 Front View Figure 12 Rear View...
Страница 119: ...VCore Page 119 VCore Figure 13 Top View Figure 14 Bottom View...
Страница 138: ......
Страница 167: ...Serial and Ethernet Control Page 167 Control Example Send Command AHJ 0D enables port A Response R 0D...
Страница 172: ......