Removing and Adding Modules
Network Interface (NI) Modules
page 5-30
OmniSwitch 8800 Hardware Users Guide
December 2004
Module Types and Slot Positions
When installing modules in the chassis, consider the following:
•
NI modules may be installed in any slot position from 1 through 16.
•
CMMs may be installed in slots A or B.
•
NI modules cannot be installed in CMM slots A or B; likewise, CMMs cannot be installed in any NI
slot position.
•
At least four (4) SFMs must be installed in SFM slots 1 through 5 on the back of the chassis. (You can
install SFMs in all five slots for redundancy.)
More Information on Slot Numbering.
For a diagram showing the chassis layout and slot positions, refer
to
Chapter 2, “Chassis and Power Supplies.”
Removing a Module
To remove a CMM or NI module from the chassis, follow the steps below.
Note.
To remove an SFM, see
Chapter 4, “Switch Fabric Module (SFM).”
1
First, loosen the module’s two captive screws that secure the module to the chassis. If necessary, use a
flat-blade screwdriver to loosen the screws. Be sure that both captive screws are completely disengaged
from the threaded holes in the chassis before continuing.