3 Troubleshooting Functional Failures During Operation
86
3.17 Power saving functionality failures
3.17.1 LED brightness control is disabled
If a problem occurs in LED brightness control during a power saving operation, perform the
check procedure described in the following table.
Table 3-33
Problems in power saving operation and action to take
No.
Items to check and commands
Action
1
The LEDs do not light when the
status of the ports changes to link
up.
Perform the following procedure:
1.
Use the
show
system
operation command to check the
information displayed for
Brightness
mode
.
off
displayed:
LED operation is disabled.
economy
displayed:
LED operation is set to power saving brightness.
2.
Use the
show
power-control
schedule
operation
command to check whether the problem occurred within the
scheduled time range.
Scheduled time range:
Execute the
schedule-power-control
port-led
configuration command with
enable
specified.
Normal time range:
Execute the
system
port-led
configuration command
with
enable
specified.
2
When the status of the ports
changes to link up, the LEDs do not
light with the normal brightness
(automatic operation is disabled).
Use the
show
system
operation command to check the
information displayed for
Brightness
mode
.
normal
displayed:
LED operation is set to normal brightness. Check the setting
of the
system
port-led
trigger
configuration
command.
If
interface
is not set in the
system
port-led
trigger
command, no physical port is specified as the trigger for
automatic operation. Specify a physical port as the trigger for
automatic operation.
Other than above:
Check the configuration.
3
When a memory card is inserted or
removed, the LEDs do not light with
the normal brightness (automatic
operation is disabled).
Use the
show
system
operation command to check the
information displayed for
Brightness
mode
.
normal
displayed:
LED operation is set to normal brightness. Check the setting
of the
system
port-led
trigger
configuration
command.
If
mc
is not set in the
system
port-led
trigger
command, insertion or removal of a memory card is not
specified as the trigger for automatic operation. Specify the
insertion or removal of a memory card as the trigger for
automatic operation.
Other than above:
Check the configuration.
Содержание AX2500S
Страница 1: ...AX2500S Troubleshooting Guide AX25S T001X 60...
Страница 6: ......
Страница 34: ...1 Overview 8...
Страница 40: ...2 Troubleshooting Switch Failures 14...
Страница 106: ...3 Troubleshooting Functional Failures During Operation 80 config...
Страница 116: ...3 Troubleshooting Functional Failures During Operation 90...
Страница 121: ...95 5 Line Testing 5 1 Testing a line...
Страница 126: ...5 Line Testing 100...
Страница 127: ...101 Appendix A Detailed Display Contents of the show tech support Command...