6.13.4 Performing a zero offset of a MFC
At regular intervals, a zero offset of the MFCs should be performed to adjust
minimum flow deviations.
Prerequisites
•
To guarantee the optimum operating temperature, the system must be
switched on at least 4 hours before performing a zero offset of an MFC.
Preparing the
system
1
In AIXACT, set the setpoint of the corresponding MFC to zero
2
Make sure that the entire system is on atmosphere pressure
3
Close the inlet valves for the process gas supply
4
Wait approx. 3 minutes to guarantee an absolute zero flow
5
In AIXACT, make sure that the deviation of the MFC is less than 1% of
the maximum configurable flow value. Otherwise the MFC must be
replaced.
In AIXTRON systems the following MFC types are used:
•
Bronkhorst High Tech, see Fig. 6-36,
176
•
Horiba Stec, see Fig. 6-37,
177
Zero offset for
Bronkhorst MFC
1
Press the push button on the back side of the MFC and keep it pressed
•
After a short time, the red LED will be illuminated
•
Then the green LED will be illuminated
Fig. 6-36
Zero offset for Bronkhorst MFC
A Push button
B LEDs
2
Now release the push button
The zeroing procedure starts and the LEDs will be flashing until the zeroing
procedure is finished.