11-28
CONTROL SYSTEM
SM YAZDCI 1-A.1 GB
The current is the AC current of the unit.
o
The models A, b, C, and d will be presented -A-, -b-, -c-, and -d- respectively.
o
11.9 Jumper
settings
ODU4
ODU3
ODU2
ODU1
ODU0
ODU
Model
Compressor Type
Single Split
Multi Split
ON
OFF
OFF
OFF
OFF
P (DCI80)
Sanyo
Mitsubishi
ON
OFF
OFF
OFF
ON
Q
ON
OFF
OFF
ON
OFF
R
ON
OFF
OFF
ON
ON
S
ON
OFF
ON
OFF
OFF
T
ON
OFF
ON
OFF
ON
U
ON
OFF
ON
ON
OFF
V
ON
OFF
ON
ON
ON
W
ON
ON
OFF
OFF
OFF
X
ON
ON
OFF
OFF
ON
Y
ON
ON
OFF
ON
OFF
Z
ON
ON
OFF
ON
ON
AA
ON
ON
ON
OFF
OFF
AB
ON
ON
ON
OFF
ON
AC
ON
ON
ON
ON
OFF
AD
ON
ON
ON
ON
ON
AE
11.10 System
Parameters
11.10.1 General
parameters
#
Name
Default Value
Units
1.
MinOFFTime
3
Minute
2.
MinONTime
3
minute
3.
HzDown1
3
Hz/min
4.
HzDown2
5
Hz/min
5.
DImin
30
minute
6.
DImax
120
minute
7.
TimeD
1
minute
8.
DTmin
2
minute
9.
DIT
10
minute
10.
CTMRUP
10
minute
11.
DIF
30
minute
12.
TCT
240
second
13.
HSTOH1
72
°C
14.
HSTOH2
76
°C
15.
HSTOH3
80
°C
16.
HSTOH4
84
°C
17.
HSTOH5
88
°C
18.
HSTOHDelta1
-1
NA
19.
HSTOHDelta2
1
NA
20.
BalanceTime
5
minute
21.
DEICT1
60
second
22.
DEICT2
36
second
23.
DEICT3
6
second
24.
DSTF
12
25.
DeiceFreqChRV
0
Hz
26.
OMTOH1
58
°C
27.
OMTOH2
60
°C
28.
OMTOH3
62
°C
29.
OMTOH4
64
°C
30.
OMTOH5
66
°C
31.
ICTOH1
46
°C
32.
ICTOH2
49
°C