11-30
CONTROL SYSTEM
SM YAZDCI 1-A.1 GB
#
Name
P
(DCI80)
Unit
40.
EEV_Active_H_SC
10
°C
41.
EEV_Active_H_SC_Crct
1
°C
42.
EnableExceedCond
0
43.
OVRPWR1
3050
Watt
44.
OVRPWR2
3150
Watt
45.
OVRPWR3
3200
Watt
46.
OVRPWR4
3300
Watt
47.
OVRPWR5
3400
Watt
48.
OVRPWRPS1
2300
Watt
49.
OVRPWRPS2
2450
Watt
50.
OVRPWRPS3
2600
Watt
51.
OVRPWRPS4
2750
Watt
52.
OVRPWRPS5
2900
Watt
53.
OVRPWRTcnst
5
Seconds
54.
MinSumCapCode1
2
NA
55.
MinSumCapCode2
2
NA
56.
MinSumCapCode3
3
NA
57.
MinSumCapCode4
4
NA
58.
MaxSumCapCode1
2
NA
59.
MaxSumCapCode2
4
NA
60.
MaxSumCapCode3
5.5
NA
61.
MaxSumCapCode4
6
NA
62.
Max_IDU_Number
4
NA
63.
InstTestCompSpeed
35
64.
InstTestEEV
180
Step
11.10.3
Indoor Units SW Parameters
11.10.3.1 General Parameters for All Models:
Parameters defining the indoor fan speed as a function of Indoor Coil temperature in heat mode
(ICT):
11.10.3.1.1 Parameters for defrost protection:
ICTST Speed
ICT to stop indoor fan
25
ICTVLSpeed
ICT to go down to very low speed
28
ICTLSpeed
ICT to start in very low speed
30
ICTHSpeed
ICT to start in increase speed from very low
32
ICTTSpeed
ICT to enable Turbo fan speed
40
ICTDef1
ICT to go back to normal
8
ICTDef2
ICT to ‘stop rise’ when ICT decrease
6
ICTDef3
ICT to ‘stop rise’ when ICT is stable
4
ICTDef4
ICT to ‘Hz Down’ when ICT decrease
2
ICTDef5
ICT to ‘Hz Down’ when ICT is stable
0
ICTDef6
ICT to stop compressor
-2
11.10.3.1.2 Parameters for indoor coil over heating protection:
ICTOH1
ICT to go back to normal
45
ICTOH2
ICT to ‘stop rise’ when ICT increase
48
ICTOH3
ICT to ‘stop rise’ when ICT is stable
52
ICTOH4
ICT to ‘Hz Down’ when ICT increase
55
ICTOH5
ICT to ‘Hz Down’ when ICT is stable
60
ICTOH6
ICT to stop compressor
62