2-10
PRODUCT DATA SHEET
SM YAZDCI 1-A.1 GB
2.3.15
DLS018 DCI Specifications
Model Indoor Unit
DLS018 DCI
Installation Method of Pipe
Flared
Power supply
V/Ph/Hz
220-240/1/50
INDOOR
Fan type & quantity
Centrifugal x 1
Fan speeds
H/M/L
RPM
630/530/425
Air flow
(1)
H/M/L
m3/hr
1170/875/730
External static pressure
Min
Pa
25
Sound power level
(2)
H/M/L
dB(A)
55/53/50
Sound pressure level
(3)
H/M/L
dB(A)
42/37/34
Moisture removal
l/hr
1.0
Condenstate drain tube I.D
mm
22
Dimensions
WxHxD
mm
770x690x260
Net Weight
kg
29
Package dimensions
WxHxD
mm
959x854x315
Packaged weight
kg
31
Units per pallet
units
6
Stacking height
units
6
2.3.16
PRIME009 DCI Specifications
Model Indoor Unit
PRIME009 DCI
Installation Method of Pipe
Flared
Power supply
V/Ph/Hz
220-240/1/50
INDOOR
Fan type & quantity
Crossflow x 1
Fan speeds
H/M/L
RPM
1200/1050/850
Air flow
(1)
H/M/L
m3/hr
420/350/270
External static pressure
Min
Pa
0
Sound power level
(2)
H/M/L
dB(A)
54/50/47
Sound pressure level
(3)
H/M/L
dB(A)
39/35/32
Moisture removal
l/hr
1
Condenstate drain tube I.D
mm
16
Dimensions
WxHxD
mm
680x250x185
Net Weight
kg
7
Package dimensions
WxHxD
mm
740x320x265
Packaged weight
kg
10
Units per pallet
units
36 units per pallet
Stacking height
units
9 levels
NOTE:
(1)
Rating conditions in accordance with ISO 5151 and ISO 13253 (for ducted units) and EN14511.
(2)
Airflow in ducted units; at nominal external static pressure.
(3)
Sound power in ducted units is measured at air discharge.
(4)
Sound pressure level measured at 1 meter distance from unit.