2-3
PRODUCT DATA SHEET
SM YAZDCI 1-A.1 GB
2.3
Indoor Units Data
2.3.1
PNX009 DCI Specifications
Model Indoor Unit
PNX009 DCI
Installation Method of Pipe
Flared
Power supply
V/Ph/Hz
220-230V/1 Ph/50 Hz
INDOOR
Fan type & quantity
Crossflow x 1
Fan speeds
H/M/L
RPM
1050/900/800
Air flow
(1)
H/M/L
m3/hr
530/430/330
External static pressure
Min
Pa
0
Sound power level
(2)
H/M/L
dB(A)
51/ - /39
Sound pressure level
(3)
H/M/L
dB(A)
39/ - /26
Moisture removal
l/hr
1
Condenstate drain tube I.D
mm
16
Dimensions
WxHxD
mm
810x285x210
Net Weight
kg
11.5
Package dimensions
WxHxD
mm
870x356x282
Packaged weight
kg
14
Units per pallet
units
28
Stacking height
units
7 levels
2.3.2
PNX012 DCI Specifications
Model Indoor Unit
PNX012 DCI
Installation Method of Pipe
Flared
Power supply
V/Ph/Hz
220-230V/1 Ph/50 Hz
INDOOR
Fan type & quantity
Crossflow x 1
Fan speeds
H/M/L
RPM
1100/950/800
Air flow
(1)
H/M/L
m3/hr
550/450/350
External static pressure
Min
Pa
0
Sound power level
(2)
H/M/L
dB(A)
52/ - /39
Sound pressure level
(3)
H/M/L
dB(A)
40/ - /26
Moisture removal
l/hr
1.5
Condenstate drain tube I.D
mm
16
Dimensions
WxHxD
mm
810x285x210
Net Weight
kg
11.5
Package dimensions
WxHxD
mm
870x356x282
Packaged weight
kg
14
Units per pallet
units
28
Stacking height
units
7 levels
NOTE:
(1)
Rating conditions in accordance with ISO 5151 and ISO 13253 (for ducted units) and EN14511.
(2)
Airflow in ducted units; at nominal external static pressure.
(3)
Sound power in ducted units is measured at air discharge.
(4)