Indoor unit model code.
This switch for changing the model code information of indoor unit PCB.
INDOOR UNIT MODEL CODE
SW4-1
SW4-2
Type
SW4-3
54
OFF
OFF
ON
ON
45
ON
OFF
OFF
ON
36
OFF
OFF
OFF
ON
30
ON
ON
ON
OFF
25(24)
OFF
ON
ON
OFF
20(22)
ON
ON
OFF
OFF
18
OFF
ON
OFF
OFF
14
ON
OFF
ON
OFF
12
OFF
OFF
ON
OFF
9
ON
OFF
OFF
OFF
7
OFF
OFF
OFF
OFF
SW4-4
MODEL CODE
5-2 Frost prevention setting switch
(3) SW4 setting (Never change at the site)
(4) SW5 setting
5-1 Wireless remote controller custom code switch
Decid the custom code and restrict the type of infrared control signal, in order to prevent
mixing of multiple indoor unit signals.
Remote controller custom code switch
OFF
OFF
SW5-1
OFF
ON
Type A
Custom code
ON
ON
ON
SW5-2
Type B
Type C
Type D
(
Factory setting)
5-3 Draft prevention setting switch (only for cassette type)
Set the flap angle of cassette type unit.
Draft prevention switch
Normal position
OFF
SW5-4
Draft prevention position
ON
Flap angle
(
Factory setting)
OFF
Normal position
Draft prevention position
35 - 65
25 - 65
Flap angle
Flap angle
*If air conditioning cooling operation is performed in
long time and a humid place, there is a possibility
that waterdrop may hang down from a blow-off mouth.
An air flow direction, by moving the flap angle horizontally,
It can prevent that a cold wind directly hits.
1. Press the MASTER CONTROL button for
more than five seconds to start the code
change.
2. Press the (+) or (-) button to select the
desired code.
3. Press the MASTER CONTROL button again
to end the code change.
A B C D
02-12
1 C / 7 C
OFF
SW5-3
ON
Starting / Completing condition
(
Factory setting)
4 C / 8 C
It selects and shifts the starting and completing condition
based on heat exchanger middle temperature
for the frost prevention control.
Содержание AO54FJ
Страница 5: ...1 TEST RUN TM SERIES R410A ...
Страница 14: ...2 FUNCTION OF PRINTED CIRCUIT BOARD TM SERIES R410A ...
Страница 39: ...3 INVERTER CONTROL TM SERIES R410A ...
Страница 45: ...4 OUTDOOR UNIT OPERATION CONTROL TM SERIES R410A ...
Страница 54: ...5 INDOOR UNIT OPERATION TM SERIES R410A ...
Страница 70: ...6 TROUBLE SHOOTING TM SERIES R410A ...
Страница 128: ...7 INSTALLATION TM SERIES R410A ...
Страница 140: ...8 REFRIGERANT CAUTION R410A TM SERIES R410A ...
Страница 149: ...9 APPENDING DATA1 UNIT TM SERIES R410A ...
Страница 155: ...COMPACT DUCT TYPE MODELS AR7 AR9 AR12 AR14 AR18 AR22 9 3 WIRING DIAGRAM 9 3 1 INDOOR UNIT 09 06 ...
Страница 156: ...LOW STATIC PRESSURE DUCT TYPE MODELS AR25 AR30 ARXB25 ARXB30 09 07 ...
Страница 157: ...MODELS AR36 AR45 09 08 ...
Страница 158: ...COMPACT CASSETTE TYPE MODELS AU7 AU9 AU12 AU14 AU18 09 09 ...
Страница 159: ...CASSETTE TYPE MODELS AU20 AU25 AU30 09 10 ...
Страница 160: ...MODELS AU36 AU45 AU54 09 11 ...
Страница 161: ...COMPACT WALL MOUNTED TYPE MODELS AS7 AS9 AS12 AS14 09 12 ...
Страница 162: ...WALL MOUNTED TYPE MODELS AS18 AS24 AS30 09 13 ...
Страница 163: ...HEAT PUMP TYPE MODEL AO54UJ 9 3 2 OUTDOOR UNIT 09 14 ...
Страница 164: ...COOLING ONLY TYPE MODEL AO54FJ 09 15 ...