05-09
5-6-2 Auto Restart
(1) The air conditioner restarts with the previous setting operation.
(2) When the air conditioner restarts for heating operation, the "COLD AIR DISCHARGE PREVENTION FUNCTION"
operates.
5-6-3 Icing Protection Control
The icing of the indoor heat exchanger is prevented during the cooling and dry mode operation.
(1) Starting Condition
Heat exchanger middle temperature =< T
A
Comperessor is operation more than 10 minutes.
(2) Operation
EEV is fully opened.
Fan is at the setting amount.
(3) Completing Condition
Heat exchanger middle temperature >= T
B
After more than 5 minutes
*
Drain pump turns off at 60 minutes past the completion of the icing protection operation.
T
A
and T
B
are selected by DIP-SW.
DIP-SW 5-3
T
A
T
B
OFF
ON
1
4
7
8
5-6-4 Cold Air blowing protection control
During the heating operation, the cold air blowing is protected.
The indoor fan operation is limited at the starting the heating mode when the heat exchanger middle temperature
is higher than 27 C.
5-6-5 Defrosting Operation, Oil Recovery Operation
[Defrosting Operation] : It prevents the heating capacity decrease due to the adhered ice on the outdoor heat
exchanger.
[Oil Recovery Operation] : It periodically returns the residual refrigerantion oil in the indoor unit and the connection
piping back to the outdoor unit, and prevents the compressor oil level from decreasing.
Indoor Unit LED : Operation LED
3 sec ON 1 sec OFF
Blinking
Indoor Fan : Stop
Indoor EEV : Control pulse
*
During the above operation, a refrigerant noise may be heard from the indoor unit.
Содержание AO54FJ
Страница 5: ...1 TEST RUN TM SERIES R410A ...
Страница 14: ...2 FUNCTION OF PRINTED CIRCUIT BOARD TM SERIES R410A ...
Страница 39: ...3 INVERTER CONTROL TM SERIES R410A ...
Страница 45: ...4 OUTDOOR UNIT OPERATION CONTROL TM SERIES R410A ...
Страница 54: ...5 INDOOR UNIT OPERATION TM SERIES R410A ...
Страница 70: ...6 TROUBLE SHOOTING TM SERIES R410A ...
Страница 128: ...7 INSTALLATION TM SERIES R410A ...
Страница 140: ...8 REFRIGERANT CAUTION R410A TM SERIES R410A ...
Страница 149: ...9 APPENDING DATA1 UNIT TM SERIES R410A ...
Страница 155: ...COMPACT DUCT TYPE MODELS AR7 AR9 AR12 AR14 AR18 AR22 9 3 WIRING DIAGRAM 9 3 1 INDOOR UNIT 09 06 ...
Страница 156: ...LOW STATIC PRESSURE DUCT TYPE MODELS AR25 AR30 ARXB25 ARXB30 09 07 ...
Страница 157: ...MODELS AR36 AR45 09 08 ...
Страница 158: ...COMPACT CASSETTE TYPE MODELS AU7 AU9 AU12 AU14 AU18 09 09 ...
Страница 159: ...CASSETTE TYPE MODELS AU20 AU25 AU30 09 10 ...
Страница 160: ...MODELS AU36 AU45 AU54 09 11 ...
Страница 161: ...COMPACT WALL MOUNTED TYPE MODELS AS7 AS9 AS12 AS14 09 12 ...
Страница 162: ...WALL MOUNTED TYPE MODELS AS18 AS24 AS30 09 13 ...
Страница 163: ...HEAT PUMP TYPE MODEL AO54UJ 9 3 2 OUTDOOR UNIT 09 14 ...
Страница 164: ...COOLING ONLY TYPE MODEL AO54FJ 09 15 ...