Page 5
Air Techniques, Inc.
AS12, AS22, AS50, AS70,
AS12C, AS22C, & AS50C
I n t e r n a t i o n a l
Must be operated at a maximum of 50% duty cycle with the maximum on time of 5
minutes .
If a Remote Control Panel is being used, ALL switches on the face of the compressor
Control Box must be in the ON position .
If a Remote Control Panel is not being used, be sure that the yellow and the orange
wires are connected to one another . These wires are located on the pressure switch .
The power switches located on the face of the compressor Control Box are the power
control for each motor .
Note:
Compressor motors are designed to run together . Do not run one head at a time
unless one head has failed and you are waiting for service .
The motor circuit breaker must be kept in the ON position and should not be used as a
switch .
OPERATING INFORMATION
Choosing the correct size
AIRSTAR
for your practice depends on the number of air users and
the anticipated air demand . To assure optimum compressor operation, the air demands should
not exceed the number of air handpiece users shown in the chart below:
SIZING GUIDE
Model
Recommended
Number of Users
Number of
Heads
Number of
Motors
AS12INT
1 - 2
1
1
AS12CINT
AS22INT
2 - 3
2
1
AS22CINT
AS50INT
5 - 7
4
2
AS50CINT
AS70INT
7 - 10
6
3
AIRSTAR models AS12INT, AS22INT, AS50INT and AS70INT do not include a sound cover,
which may be purchased as an optional accessory . (See page 16 .)
AS12CINT, AS22CINT and AS50CINT models do include a sound cover as part of the system .