INSTRUCTIONS FOR USE
AGS 1800 - 2000 EN-HV (HVB)
Rev.9/2018
112
After cleaning the sprayer with a detergent, fill at least 1/5 of the tank with clean water and repeat the
cleaning process. Make sure that you have cleaned all elements that have come in contact with the
insecticide or the detergent.
Make sure that you have precisely cleaned all filters. Be careful not to damage the fabric on the filter
insert while cleaning filters. If the filter insert is damaged, replace it with a new one. (A more precise
description about cleaning of the pressure filter can be found in the chapter “SUCTION FILTER–
CLEANING FILTER INSERT”).
At the end of the cleaning process, clean all nozzles. Nozzles can be cleaned only by means of a soft
brush, compressed air or water. You can damage the nozzle when cleaning it with a hard item.
16.6
MAINTENANCE AND STORAGE AFTER SEASON
When the spraying season is over, find some time and prepare the spraying appliance for storage.
Before storing the appliance, thoroughly clean the inside and the outside of the sprayer (regulator,
pump, sieves, selection valves, nozzles, etc.). When the cleaning is done make sure that there is no
water left in the valves, the filters, the pump, the nozzles, etc. Do not maintain the sprayer until it has
not been thoroughly cleaned.
16.6.1
HOSES
Check the tightness of all hoses and hose junctions. Replace damaged hoses with new ones. A
damaged hose cost you a lot of time during spraying.
16.6.2
PAINT
Some insecticides contain solvents which affect the paint. Clean the corrosion off of colourless parts of
the spraying appliance and apply some new paint.
16.6.3
RESERVOIR
Make sure that there are no rests of insecticide inside the reservoir. Chemical agents must not stay in
the reservoir for a long time, since they can fast shorten the durability of the reservoir and other parts.
Make sure that the outflow valve is opened.
16.6.4
PRESSURE REGULATOR
Protect the pressure regulator against moisture and dust. It is recommended to grease moving parts
with WD-40 or oil. There are further instructions about the maintenance of the regulator in chapter
"PRESSURE REGULATOR MAINTENANCE".
WARNING: Be careful while handling detergents; follow the instructions of the
manufacturer!
WARNING: In the case your spraying equipment is being cleaned by a high-
pressure cleaning appliance, it is recommended to grease all moving parts after
every single cleaning !