Chapter 9
Fiber Cable Testing Overview 74
WireScope 350
DualRemote 350
Fiber
Sma
Fiber
Sma
Conventional Loss Testing Configuration:
Single Fiber Tested
850 nm
4 km multimode
50 km singlemode
Double-Ended Test Configuration - Testing Single Fibers
Single Ended measurements require that fibers be tested in pairs in a loopback
configuration. The advantage of Single Ended testing is that only one Fiber
SmartProbe
+
is required.
Fiber
Sma
Both fibers in pair
tested simultaneously
Fiber Patch Cord
Used as Loopback
2 km multimode
25 km singlemode
WireScope 350
Single Ended Test Configuration
Connect the Fiber SmartProbe
+
to the WireScope 350 and it automatically
configures itself for fiber optic specific testing.