149
Appendix B, Manual Changes
Change 1
"Generator Output Path" on page 125
(RF IN/OUT and RF OUT only connector)
NOTE:
To meet generator output path specifications, the input signal must be from the Agilent
8920A,B, Agilent 8921A,D, or Agilent 8924C Test Set with the following characteristics:
Frequency Range:
810 MHz to 995 MHz
Level Range:
−
70 dBm to
−
7 dBm.
Frequency
Frequency Range:
Through Path:
824 MHz to 849 MHz
869 MHz to 894 MHz
Conversion Path:
1710 MHz to 1785 MHz
1805 MHz to 1910 MHz
1930 MHz to 1990 MHz
Spectral Purity
* Offset
≥
5 kHz
** For carrier levels >
−
100 dBm
Table 18
Spurious
Type of
spurious
824 to 849 MHz,
869 to 894 MHz
894<
to <1710 MHz
1710 to 1990 MHz
Harmonics
<
−
30 dBc
—
<
−
30 dBc
Non-Harmonics
<
−6
0 dBc
*
<
−25
dBc
**
<
−6
0 dBc
*