Installation - 21
Ins
ta
lla
ti
o
n
NOTE
Air filter and connection are located on the lower left rear
of the Main Cabinet. Verify the input air supplied is at
least 8
0
psi (5.63Kg/cm
2
), and adjust as required.
17.
Main Cabinet Inspection
— Inspect the inside of
the Main Cabinet to:
•
verify that there are no loose items
•
remove excess grease from the X and Y axes lead
screws with a clean cloth.
•
remove all stage securing ties and desiccant
18.
Air Filter Installation
— Install the air filter on top
of the x-ray tower. It fits into a beveled area on top
of the tower
19.
Install Camera Power Supply -
Install the SMD
camera power supply under the 5DX.
a.
Remove the 3/8 in. nuts and washers
b.
Install the supply and replace the nuts and washers
and tighten
c.
Connect the frame grabber cable (E7200-61734),
trigger cable (E7200-61733) and shutter cable
(E7200-61736).
Be careful with the frame grabber
cable because the pins are fragile.
d.
Connect the power cord between the power supply
and the camera.
e.
Connect the power cord to the supply and turn the
switch on.
20.
AC Mains Hookup
— Work with the customer
electrician to provide main power installation to
local code. For general service feed location, see
. Normal requirements are: