86
7713397 R2
Figure 102.
Gravity Fill Cable Route*
FILL DRYER SWITCH
(2 Possible locations)
LOW DRYER SWITCH
Figure 103.
Level Auger Cable Route*
LOW DRYER SWITCH
FILL DRYER SWITCH
FILL DRYER SWITCH
* The illustrations show cable routes for several possible switch locations.
4.7.7 Install Moisture/Temperature Sensors
Moisture/Temperature Sensor Overview
• The combination moisture/temperature sensing unit (059250W) has a moisture sensing “fin” and a
temperature sensing probe directly below it. The sensor provides 0 to 10 VDC signals for both temperature
and moisture, which the embedded DryerMaster converts to grain moisture and temperature readings.
• One sensor is located at the top of the dryer for reading INLET grain moisture and temperature.
• One sensor is located at the dryer grain discharge chute for reading OUTLET grain moisture and
temperature.
CONTINUOUS-FLOW GRAIN DRYER – COMMANDER CONTROL