7713397 R2
83
4.7.6 Install the Fill Switch and Low Switch
• The installation location of the fill and low switches depends upon the style of fill and configuration of the
intake grain supply.
• The various installation positions come from the factory, covered with a 059166 cover plate.
• Determine the correct switch position for the equipment configuration.
• Install the switches in the locations shown in
–
. Leave any unused locations covered.
• Connect the wiring as described in
Connect Fill Switch and Low Switch on page 85
.
Roof with Gravity Fill System
Gravity fill system intake grain at the center. The intake auger system must match to this location.
Figure 97.
Gravity Fill Switch and Cover Locations
FILL AUGER EXIT CHUTE
NEEDS TO MATCH UP TO
THIS FLANGE
Figure 98.
Hole Cover and Switch Flanges
ROTARY SWITCH HOLE
COVER PLATE
#059166
FILL DRYER SWITCH FLANGE IS 30 DEG.
LOW DRYER SWITCH FLANGE IS 45 DEG.
CONTINUOUS-FLOW GRAIN DRYER – COMMANDER CONTROL