Software Manual EN
◼
SE-24
◼
01.06.2022
◼
V1.3
49
–54
Step
Work to be done
OK
5
Ensure that the power supply to the SE-24 servo controller (SE-24/SE-48
power cable, wire no. 3) can be disconnected by a suitable Emergency-
Stop switching device if necessary. The electronics supply and ground
(SE-24/SE-48 power cable, wires 2 + 1) must however be maintained.
Please see the SE-24 operating instructions for further notes.
6
Connect the SE-24/SE-48 power cable to the Afag SE-24 servo controller.
Please see the SE-24 operating instructions for further notes.
7
Ensure that the afagTools parameterization program is installed on your
PC.
Please see chapter
„4.2 Installation afagTools program
“
in this manual for installation instructions of the program.
8
Connect the SE-24 programming cable to the Afag SE-24 servo controller.
Please see the SE-24 operating instructions for further notes.
9
Connect the SE-24 stick to the SE-24 programming cable.
10
Insert the SE-24 stick into the PC.
If the hardware installation wizard opens select the path for driver
installation as per chapter
„4.3.3 Installation of the SE-24 stick
in this manual.
11
Ensure that the interface cables to a higher level control system (PLC) are
not yet connected.
Depending on the controller model this applies to the following cables:
The SE-24 I/O cable for the SE-24 I/O servo controller.
The bus cables for servo controllers with fieldbus connection (Profibus,
EtherCAT, CANopen).
12
Switch on the power supply to the electronics.
13
Open the afagTools parameterization program and touch the "Search
devices" button.
Transfer the ID of the device with which you want to connect from the
“Device list” in the “NodeID” box and click on “Connect device".
For further notes please see chapter
in this manual.