5.8.2 Actual application status
Status (hex)
Current actual application status in hexadecimal notation.
Status bits
Detailed information are to be found in the interface descriptions of the corresponding
manuals for the various SE-24 servo controller models.
Ready
The device is ready-to-operate, there are no active errors
pending.
Comment: Corresponds to the
“ready” interface signal.
Enabled
The controller is active and the motor is energized.
Comment:
Corresponds to the “drive_enable_ok” interface
signal.
Homing done
A valid reference run was executed.
Comment:
Corresponds to the “ref_valid” interface signal.
Move OK
A movement was executed.
Comment:
Corresponds to the “move_ok” interface signal.
ACK
Toggle bit which signalizes that a job (in the application)
was recognized.
Comment: This signal is used internally.