5.8.8 Reverse mode
Reverse mode is used to determine the parameters for later positioning during start-up.
Example
Pos.X selection box
Using this selection box you can select any set from the 15
moving sets which is to be executed first when starting the
reverse mode.
Pos.Y selection box
Using this selection box you can select any set from the 15
moving sets which is to be executed as the second one
when starting the reverse mode.
Pos.X <--> Pos.Y
Reverse
mode is started when the “Pos.X <--> Pos.Y”
button is pressed. That means that the two selected moving
sets are approached continuously one after the other.
The reverse
mode can be stopped by clicking the “STOP”
button. In this case movement is braked with the braking
acceleration defined for the quick stop.
The reverse mode can also be interrupted by clicking the
“Disable” button. The motor will then coast to stop.
Comment: The function is only active when controller
enable was activated and a valid reference run was
executed.
CAUTION
A movement is triggered after the “Pos.X <--> Pos.Y” button
was actuated.
NOTE
Changes of the moving data sets used for the reverse mode are
ignored when reverse mode is active. The reverse mode must be
stopped and then restarted again in order to retrieve the changes.