Software Manual EN
◼
SE-24
◼
01.06.2022
◼
V1.3
41
–54
Settings for the “Move OK” signal in current mode.
Curr. window
This value corresponds to the tolerance for the current
window and is placed as a sym/- value around the
target current.
Comment: Double the value corresponds to the
“current_tolerance” value in Figure 4: Current mode.
Curr. window time
This value sets the delay time from the moment when the
actual current value is in the c
urrent window until the “Move
OK” signal is triggered.
Comment:
This
value
corresponds
to
the
“current_delay_time” value in Figure 4: Current mode.
Curr. gating time
This value fades out the starting current when a movement
is started.
After start-
up the “Move OK” signal is not triggered though
the current is within the current window.
Comment:
This
value
corresponds
to
the
“current_gating_time” value in Figure 4: Current mode.
Comment:
The “Move OK” signal is triggered after the current fade out time and the delay
time for the current in the current window have passed.
X = position_value (actual position)
Y = target_position (abortion position)
Current = target_current
Figure 4: Current mode