51
QS2 Series Low Voltage Servo Drive
No. Parameter name
Function
Range
Input the encoder wire number of the motor, generally
1024, 2048, 2500, 3000 and 5000;
Note that the it needs restarting after modification of the
parameter to make it valid; default value is 2500;
P53
Encoder type
Only the motor model set as (P2=9999) can the parameter be
valid;
Setting as 0 means the common non-wire-saving encoder while
setting as 1 means wire-saving;
Note that the it needs restarting after modification of the
parameter to make it valid; default value is 0;
0
-
1
P54
Number of
pole-pairs
Only the motor model set as (P2=9999) can the parameter be
valid;
The setting value means the number of pole - pairs
Note that the it needs restarting after modification of the
parameter to make it valid; default value is 4;
2
-
6
P55
Deviation
angle
The setting value means the deviation angle of the motor
between the electric degree and zero-point;
note that the it needs restarting after modification of the
parameter to make it valid; default value is 210;
0
-
2500
P56
Rated current
Only the motor model set as (P2=9999) can the parameter be
valid;
The setting value means the rated current of the motor, only
affecting the current protection function of the motor but not
the operation of the motor;
Setting unit (0.1A)
0
-
100