User Manual of TV5600-B01 Series Dispensing Control System
91
2)
Circle center coordinate 1: The circle center coordinates of the 1st axis
of the plane where the ellipse is located
3)
Circle center coordinate 2: The circle center coordinates of the 2nd axis
of the plane where the ellipse is located
4)
Ellipse radius 1: Radius of the first axis of the ellipse plane
5)
Ellipse radius 2: Radius of the second axis of the ellipse plane
6)
Whether the instruction is executed: Whether this programming point
(processing instruction) is executed during processing
12
End point of
ellipse
Specify the end point coordinates of the ellipse
1)
XYZABC coordinates: Coordinates of each axis
2)
XYZABC enable: Whether each axis participates in motion
3)
Whether the instruction is executed: Whether this programming point
(processing instruction) is executed during processing
4)
Use default speed: Select Yes to run at the speed set in the file
parameter, or else use the speed set in speed ratio * file parameter
5)
Speed ratio (%): This value is meaningful when the default value is not
used as above
13 Idle travel
Each axis moves to the specified position at the idle speed
1)
XYZABC coordinates: Coordinates of each axis
2)
XYZABC enable: Whether each axis participates in motion
3)
Whether the instruction is executed: Whether this programming point
(processing instruction) is executed during processing
4)
Use default speed: Select Yes to run at the speed set in the file
parameter, or else use the speed set in speed ratio * file parameter
5)
Speed ratio (%): This value is meaningful when the default value is not
used as above
16 Spline
Move to the specified position by Bezier spline interpolation
1)
XYZABC coordinates: Coordinates of each axis
2)
XYZABC enable: Whether each axis participates in motion
3)
Whether the instruction is executed: Whether this programming point
(processing instruction) is executed during processing
4)
Use default speed: Select Yes to run at the speed set in the file
parameter, or else use the speed set in speed ratio * file parameter
5)
Speed ratio (%): This value is meaningful when the default value is not
used as above
17
End point of
spline
End point of the Bezier curve
1)
XYZABC coordinates: Coordinates of each axis
2)
XYZABC enable: Whether each axis participates in motion
3)
Whether the instruction is executed: Whether this programming point
(processing instruction) is executed during processing
4)
Use default speed: Select Yes to run at the speed set in the file
parameter, or else use the speed set in speed ratio * file parameter
5)
Speed ratio (%): This value is meaningful when the default value is not
used as above
Содержание DJ1600V1-A01
Страница 1: ...I TV5600 B01 Series Dispensing Control System User Manual ...
Страница 2: ...User Manual of TV5600 B01 Series Dispensing Control System 2 ...
Страница 15: ...User Manual of TV5600 B01 Series Dispensing Control System 15 Front view Side view Side view ...
Страница 47: ...User Manual of TV5600 B01 Series Dispensing Control System 47 ...
Страница 123: ...User Manual of TV5600 B01 Series Dispensing Control System 123 ...
Страница 131: ...User Manual of TV5600 B01 Series Dispensing Control System 131 8 AMC1600serial port AMC1600 COM1 port ...