User Manual of TV5600-B01 Series Dispensing Control System
33
※
Note: The effective level of the origin is the signal value from the input of the origin sensor
switch when the origin switch is blocked. The origin switch is in different states when it iscovered
and uncovered, or else the origin switch has been damaged.
5.05 Reset
1. -> Main interface of handheld box -> Press [Reset] button
-> system reset -> the
following may occur:
2. -> Main interface of touch screen -> Press [Reset] button -> system reset -> the following may
occur:
Reset direction is wrong: Please modify the “Motor features” of the axis –> “Reset
direction” parameter
Origin not detected: Please check whether the origin signal and the “origin effective
level” setting are correct
Reset overshoot: Please increase the reset low speed and reduce the reset high speed
reasonably, and increase the reset acceleration
Reset jitter: Please reduce the reset low speed reasonably; reduce the reset
acceleration, which is generally set at 800~15000
When resetting, the motor of one axis does not move, but the coordinates of the axis
change on the interface, please check the motor wiring.
Содержание DJ1600V1-A01
Страница 1: ...I TV5600 B01 Series Dispensing Control System User Manual ...
Страница 2: ...User Manual of TV5600 B01 Series Dispensing Control System 2 ...
Страница 15: ...User Manual of TV5600 B01 Series Dispensing Control System 15 Front view Side view Side view ...
Страница 47: ...User Manual of TV5600 B01 Series Dispensing Control System 47 ...
Страница 123: ...User Manual of TV5600 B01 Series Dispensing Control System 123 ...
Страница 131: ...User Manual of TV5600 B01 Series Dispensing Control System 131 8 AMC1600serial port AMC1600 COM1 port ...