Mounting and Wiring the Control
2-11
Installing the RF Receiver
Use any 5800 Series Wireless Receivers, such as:
RF Receiver
No. of Zones
5881L/5882L
up to 8
5881M/5882M
up to 16
5881H/5882H
up to 40 plus 16 button zones
5883,
6150RFADT
Zone Nos.: transmitters = 9-48; buttons = 49-64
1. Set Device Address to “00” as described in its instructions (set all switches to the right, “off”
position).
2. Mount the receiver, noting that the RF receiver can detect signals from transmitters within a
nominal range of 200 feet.
3. Connect the receiver's wire harness to the control's touchpad terminals. Plug the connector at the
other end of the harness into the receiver. Refer to the installation instructions provided with the
receiver for further procedures regarding antenna mounting, etc.
Notes
•
The receiver is supervised and a trouble report is sent (“CHECK 100” displayed) if communication
between the panel and receiver is interrupted, or if no valid RF signals from at least one supervised
transmitter are received within 12 hours.
If the receiver is mounted remotely:
•
Place the RF receiver in a high, centrally located area for best reception.
•
Do not locate the receiver or transmitters on or near metal objects. This will decrease range and/or
block transmissions.
•
Do not locate the RF receiver in an area of high RF interference (indicated by frequent or prolonged
lighting of the LED in the receiver; random flicker is OK).
•
Do not locate RF receiver closer than 10 feet from any touchpads to avoid interference from the
microprocessors in those units.
MOUNTING
HOLES
INTERFERENCE
INDICATOR
LED
CIRCUIT BOARD
DIP
SWITCH
ANTENNAS
(INSERT IN
RIGHT-HAND
TERMINALS)
YELLOW
RED
BLACK
GREEN
WIRING OPENING
KNOCKOUT AREA
FOR SURFACE WIRING
TO CONTROL'S
REMOTE KEYPAD
CONNECTION
POINTS.
5882
LOCATION
TO RELEASE CIRCUIT BOARD,
REMOVE SCREWS AND
BEND BACK TABS
NOTE
CIRCUIT BOARD IS MOUNTED IN
CONTROL'S CABINET. GROUNDING
LUGS (2) PROVIDED
MUST
BE INSERTED
IN LEFT-HAND TERMINALS OF ANTENNA
BLOCKS AND SECURED TO CABINET.
(SEE RECEIVER'S AND CONTROL'S
INSTRUCTIONS)
SOCKET
PLUG
MODEL NO. IS INDICATED ON CIRCUIT BOARD
5881-003-V0
INSERT IN
RIGHT- HAND
TERMINALS
Figure 9. 5881/5882 RF Receiver (cover removed)
Содержание Enterpreneur 3000EN
Страница 64: ...3000EN Series Installation Instructions 6 6...
Страница 68: ...3000EN Series Installation Instructions 8 2...
Страница 78: ...3000EN Series Installation Instructions 12 2...
Страница 82: ...13 4...
Страница 88: ...3000EN Series Installation Instructions 14 6...
Страница 92: ...3000EN SERIES INSTALLATION INSTRUCTIONS 15 4...
Страница 96: ...3000EN SERIES INSTALLATION INSTRUCTIONS 17 2 NOTES...
Страница 97: ...17 3 NOTES...
Страница 98: ...3000EN SERIES INSTALLATION INSTRUCTIONS 17 4 NOTES...
Страница 104: ...ADT Security Services Inc One Town Center Rd Boca Raton FL 33486 Copyright 2003 K5305V8s K5305V8 11 10 Rev A SIA...