3000EN Series: Installation Instructions
4-12
*166
Pager 3 Phone No.
Enter up to 20 digits
If you enter fewer than 20 digits, exit by pressing [
∗
] and next
field number. To clear entries from this field, press
∗
166
∗
.
*167
Pager 3 Characters
Enter up to 16 characters
See field
∗
161 for explanation of entries. If fewer than 16
characters, exit by pressing [
∗
] and next field number. To
clear entries from this field, press
∗
167
∗
.
*168
Pager 3 Report Options
see pager 1 reports, field *162 for
entries, except use zone list 11.
Enter the types of reports to be sent to Pager 3 for each
partition.
*169
Pager 4 Phone No.
Enter up to 20 digits
If you enter fewer than 20 digits, exit by pressing [
∗
] and next
field number. To clear entries from this field, press
∗
169
∗
.
*170
Pager 4 Characters
Enter up to 16 characters
See field
∗
161 for explanation of entries. If fewer than 16
characters, exit by pressing [
∗
] and next field number. To
clear entries from this field, press
∗
170
∗
.
*171
Pager 4 Report Options
see pager 1 reports, field *162 for
entries, except use zone list 12.
Enter the types of reports to be sent to Pager 4 for each
partition.
*172
Pager Delay Option for Alarms
0 = none
2 = 2 minutes
1 = 1 minute
3 = 3 minutes
This field determines the delay of alarm reports to the pager.
This gives the Central Station enough time to verify the
alarm report that it received, before the dialer attempts to
dial the pager.
NOTE:
This delay is for ALL pagers in the system.
Miscellaneous System Fields
*173
RF Reporting Options
0 = disable all options
1 = RF Tamper reports during disarm
2 = RF button types send low battery
reports
8 = RF low battery reports delayed 28
days
E.g., .Entering “10” (8 + 2) enables button-type transmitters
to send low battery reports, and delay all low battery reports
for 28 days.
UL Installations: RF tamper reports (“1”) and RF button low
battery reports (“2”) must both be enabled by entering “3” in
this field.
*175
Up And About Time
0 = none;
1-15 = 1 to 15 hours respectively
This option is part of an Up and About schedule (event 12)
that requires programming (see
Scheduling
section for
details). The value in this field is the time within which
activity must occur within the overall scheduled up and about
time window. If no zones are faulted or no key is pressed
within the selected time period during a scheduled Up and
About time window, a report is sent to the central station.
This can serve as a safety feature for elderly, infirm, or
disabled persons.
*176
Lack Of Usage Option
0 = disable feature
1-15 = 1-15 weeks
If the control is not armed within the selected time period, a
report is sent to the central station.
*177
Device Duration 1, 2
0 = 15 secs 6 = 2.5 min #+12 = 8 min
1 = 30 secs 7 = 3 min
#+13 = 10 min
2 = 45 secs 8 = 4 min
#+14 = 12 min
3 = 60 secs 9 = 5 min
#+15 = 15 min
4 = 90 secs #+10 = 6 min
5 = 2 min
#+11 = 7 min
These entries set the duration for output action options 5
(duration 1) and 6 (duration 2) programmed in
∗
80 Output
Function Programming.
*180
Single Zone Bypass
0 = disable; 1 = enable
If enabled, users can bypass only one zone when arming the
system.
*181
50/60 Hz AC Operation
0 = 60 Hz; 1 = 50 Hz
Select the type of AC power applied to the control.
This option is used for Real-Time Clock synchronization.
Содержание Enterpreneur 3000EN
Страница 64: ...3000EN Series Installation Instructions 6 6...
Страница 68: ...3000EN Series Installation Instructions 8 2...
Страница 78: ...3000EN Series Installation Instructions 12 2...
Страница 82: ...13 4...
Страница 88: ...3000EN Series Installation Instructions 14 6...
Страница 92: ...3000EN SERIES INSTALLATION INSTRUCTIONS 15 4...
Страница 96: ...3000EN SERIES INSTALLATION INSTRUCTIONS 17 2 NOTES...
Страница 97: ...17 3 NOTES...
Страница 98: ...3000EN SERIES INSTALLATION INSTRUCTIONS 17 4 NOTES...
Страница 104: ...ADT Security Services Inc One Town Center Rd Boca Raton FL 33486 Copyright 2003 K5305V8s K5305V8 11 10 Rev A SIA...