3000EN Series: Installation Instructions
6-4
01 Activated By:
Zone List
Activated By
0 = delete
1 = zone list
2 = zone type
3 = zone number
[
∗
] to continue
Select where the initiating event for this output definition is
to occur as follows:
0 = delete (deletes the output function and any previous
programming;-see prompt below)
1 = zone list (go to “A” prompt)
2 = zone type (go to “B” prompt)
3 = zone number (go to “C” prompt)
If you enter “0,” the following prompt appears:
Delete?
Press 1 to delete this
0 = NO, 1 = YES
output definition
.
“
A
”
01 Zn List
1
Zone List
01-08 = zone list
[
∗
] to continue
If zone list was selected, this screen appears. Otherwise skip to
the next row.
Enter the desired zone list associated with this output number.
NOTE:
Do not use pager zone lists 09-12 in output definitions.
Press [
✱
] to continue.
Enter the zone list event that will activate this output.
Enter Event
0 = restore; 1 = alarm;
Alarm
1
2 = fault; 3= trouble
NOTE:
For alarm, fault, and trouble, an event on ANY zone in
the list activates the output, but ALL zones in the list must be
restored before the output is restored.
Press [
✱
] to continue and skip to the “Output Action” prompt.
“
B
”
01 Enter Zn type
Perimeter 03
Zone Type
see list at right
If zone type was selected, this screen appears. Otherwise skip
to the next row.
Enter the desired zone type associated with this output
number. See below for a list of available zone types.
CHOICES FOR ZONE TYPES:
00 = Not Used
05 = Trouble Day/Alarm Night 14 = Carbon Monoxide††
01 = Ent/Exit #1
06 = 24 Hr Silent
16 = Fire w/verification
02 = Ent/Exit #2
07 = 24 Hr Audible
23 = No Alarm Response
03 = Perimeter
08 = 24 Hr Aux
24 = Silent Burglary
04 = Interior Follower
09 = Fire
25 = 24-Hr Non-Alarm
10 = Interior w/Delay
77 = Keyswitch Zone
12 = Monitor Zone
81 = AAV Monitor Zone
90-93 = Configurable
CHOICES FOR
SYSTEM OPERATION:
20 = Arming–Stay
36 = **At Bell Timeout***
58 = Duress
21 = Arming–Away
38 = Chime
60 = AAV
22 = Disarming
39 = Any Fire Alarm
61 = AVS/GSMV
session begin
§
31 = End of Exit Time
40 = Bypassing
62 = AVS/GSMV
session end
§
32 = Start of Entry Time
41 = **AC Power Failure
66 = Function Key†
33 = Any Burglary Alarm
42 = **System Battery Low
67 = Bell Fail
43 = Comm. Failure
68 = Telco line cut
52 = Kissoff
78 = Keyswitch Red LED
54 = Fire Zone Reset
79 = Keyswitch Green LED
** Use 0 (Any) for Partition No. (P) entry.
*** Or at Disarming, whichever occurs earlier.
† Use *57 Menu Mode to assign the function key (function “07”).
†† when used with an output function, the carbon monoxide zone type
activates upon CO alarms only. Does not activate for trouble conditions
§ automatically set when appropriate AVS Quick Command performed.
Note:
In normal operation mode:
Code + # + 7 + NN Key Entry
starts
Device NN.
Code + # + 8 + NN Key Entry
stops
Device NN.
Enter the partition in which this zone type will occur.
01 Partition
0 = any partition; 1 = partition 1;
Any partition
0
2 = partition 2; 3 = common
Press [
✱
] to continue and skip to the “Output Action” prompt.
Содержание Enterpreneur 3000EN
Страница 64: ...3000EN Series Installation Instructions 6 6...
Страница 68: ...3000EN Series Installation Instructions 8 2...
Страница 78: ...3000EN Series Installation Instructions 12 2...
Страница 82: ...13 4...
Страница 88: ...3000EN Series Installation Instructions 14 6...
Страница 92: ...3000EN SERIES INSTALLATION INSTRUCTIONS 15 4...
Страница 96: ...3000EN SERIES INSTALLATION INSTRUCTIONS 17 2 NOTES...
Страница 97: ...17 3 NOTES...
Страница 98: ...3000EN SERIES INSTALLATION INSTRUCTIONS 17 4 NOTES...
Страница 104: ...ADT Security Services Inc One Town Center Rd Boca Raton FL 33486 Copyright 2003 K5305V8s K5305V8 11 10 Rev A SIA...