3000EN Series: Installation Instructions
3-2
Touchpads
Touchpads are identified by predefined addresses as follows:
Address Touchpad Program
Field
16
touchpad
1
•
always enabled for partition 1, all sounds enabled.
NOTE: First touchpad
17
touchpad 2
•
data field *190
is address 16.
18
touchpad 3
•
data field *191
19
touchpad 4
•
data field *192
20
touchpad 5
•
data field *193
21
touchpad 6
•
data field *194
22
touchpad 7
•
data field *195
23
touchpad 8
•
data field *196
To enable touchpads:
1. Set desired address at touchpad (refer to touchpad’s instructions for setting the address).
2. Use data field program mode to enable touchpad addresses, assign a partition, enable sound
options in fields *190-*196 as shown in the table above.
3. If desired, use data field *198 to turn on the display of the partition number.
4. Set the following touchpad-related data fields as required by the installation:
*21 Quick Arm Enable, *23 Forced Bypass, *84 Auto STAY Arm, *176 Lack of Usage Option
5. If using AUI, enable each unit in field *189 and set the AUI devices to the following addresses:
AUI 1 = address 1; AUI 2 = address 2; AUI 3 = address 5; AUI 4 = address 6
Wireless Receiver, Transmitters, and Wireless Keys (keyfobs)
Receiver:
Set the receiver’s address to “00” using its DIP switches, then set the following options:
*22
RF Jam Option†
*24
RF House ID Code (if using wireless touchpads) for each partition
*67
Transmitter Low Battery Report Code†
*75
Transmitter Low battery restore report code†
*173 RF Reporting Options
Transmitters:
Use *56 or *58 Zone Programming Menu modes to program zone information and
enroll transmitters.
Wireless Keys:
Use
Wireless Key Programming Templates
section of the
*58 Expert Programming
mode
in
Section 5 Zone Programming
(page 5-6) to program zone information and enroll each
button of the wireless keys used. Once a wireless key is enrolled, it must be assigned to a user before
it becomes active. See
Adding/Deleting Security Codes
in
Section 12 System Operation
(page 12-2)
for the procedure.
Pager Programming
The system can send various reports to up to four pagers. To program pager reporting:
1. Enter the appropriate information in the following data fields
*160, *163, *166, *169 Pager Phone Numbers (for pagers 1-4 respectively)
*161, *164, *167, *170 Pager Prefix Characters (for pagers 1-4 respectively)
*162, *165, *168, *171 Pager Reporting Options by Partition (for pagers 1-4 respectively)
2. Enable Pager Delay, if desired, in field *172 (delays alarm reporting for ALL pagers)
3. Make sure appropriate user open/close pager reports are enabled using the user attribute command
(master code + [8] + user no. + [#] [5] + [1]). Users that perform actions in partition 1 will, if
enabled, attempt to report to all pagers enabled for open/close reporting in partition 1. Users that
perform actions in partition 2 will, if enabled, attempt to report to all pagers enabled for open/close
reporting in partition 2.
4. If using latchkey pager report, define the latchkey report schedule using Scheduling mode (master
code + [#] [6] [4], select event type “03”). System must be armed for the Latchkey report to be sent.
5. If using a function key to manually send a message to a pager, see Function Keys paragraph.
6. If reporting zone alarms and troubles to a pager, use *81 Zone List menu mode to assign the zones
associated with each pager (zone lists 9-12).
†
These fields must be enabled for Residential
Fire, UL Residential Burglar Alarm, and UL
Commercial Burglar Alarm installations.
Содержание Enterpreneur 3000EN
Страница 64: ...3000EN Series Installation Instructions 6 6...
Страница 68: ...3000EN Series Installation Instructions 8 2...
Страница 78: ...3000EN Series Installation Instructions 12 2...
Страница 82: ...13 4...
Страница 88: ...3000EN Series Installation Instructions 14 6...
Страница 92: ...3000EN SERIES INSTALLATION INSTRUCTIONS 15 4...
Страница 96: ...3000EN SERIES INSTALLATION INSTRUCTIONS 17 2 NOTES...
Страница 97: ...17 3 NOTES...
Страница 98: ...3000EN SERIES INSTALLATION INSTRUCTIONS 17 4 NOTES...
Страница 104: ...ADT Security Services Inc One Town Center Rd Boca Raton FL 33486 Copyright 2003 K5305V8s K5305V8 11 10 Rev A SIA...