.
Figure 31: Converter with 1 connector
Figure 32: Converter with 2 connectors
3. Close the light fixture and connect it to a CCR.
4. Energize the light fixture until there is a steady light, then turn the CCR off and unplug the light fixture.
5. Disassemble the light fixture, then remove the two-way electrical shunt (2.54 mm spacing) from the pins.
6. Assemble the light fixture and perform a functional test.
6.4.12 Resetting the Fail-open converters 48010921 and 48011111
Parts
•
Fuse resistor spare part kit: 6132.00.250 (20pcs)
Info
•
Converter with 1 connector have 2 fuse resistors
•
Converter with 2 connectors have 4 fuse resistors
Resetting / replacing the fuse resistors
1. Disconnect and disassemble the light fixture.
2. Locate the fuse resistors.
Note
Refer to
figures.
Figure 33: Converter with 1 connector
Figure 34: Converter with 2 connectors
3. Remove the fuse resistors by pulling away from the converter.
a. For converters with 1 connector, always replace both fuse resistors at the same time.
b. For converters with 2 connectors, always replace both fuse resistors related to the A/B channel that needs to be reset.
If both A and B channel needs a reset, replace all 4 fuse resistors.
RELIANCE Omni Light
Maintenance
50
Copyright
©
ADB SAFEGATE, All Rights Reserved
Содержание RELIANCE
Страница 1: ...RELIANCE Omni Light 8 inch User Manual UM 5027 Rev 1 0 2020 12 10 ...
Страница 2: ......
Страница 8: ...RELIANCE Omni Light List of Figures viii Copyright ADB SAFEGATE All Rights Reserved ...
Страница 10: ...RELIANCE Omni Light List of Tables x Copyright ADB SAFEGATE All Rights Reserved ...
Страница 22: ...RELIANCE Omni Light General Information 12 Copyright ADB SAFEGATE All Rights Reserved ...
Страница 26: ...RELIANCE Omni Light Installation 16 Copyright ADB SAFEGATE All Rights Reserved ...
Страница 36: ...RELIANCE Omni Light Operation 26 Copyright ADB SAFEGATE All Rights Reserved ...
Страница 62: ...RELIANCE Omni Light Maintenance 52 Copyright ADB SAFEGATE All Rights Reserved ...
Страница 70: ...RELIANCE Omni Light POWER TABLE 60 Copyright ADB SAFEGATE All Rights Reserved ...
Страница 72: ...RELIANCE Omni Light CABLE LOSS 62 Copyright ADB SAFEGATE All Rights Reserved ...
Страница 76: ......