3. Remove the Teflon and steel protective plates from the LED board holder.
4. Remove the prism and its gasket, see
Figure 22: Remove LED board holder
Figure 23: Remove prism and gasket
Replacement
NOTICE
The prism gaskets and the protection prism plate require replacement every time a prism is replaced. That means that
when 4 prisms have to be replaced, 4 gaskets and prism protection plates require replacement, too.
1. Lubricate the new prism gasket with CC Patron grease.
2. Place the prism gasket in the prism opening in the top cover.
3. Put the new prism into the new prism gasket, then push it all the way into the opening and hold for about a minute. See
.
Figure 24: New prism into prism gasket
4. Check that the O-ring of the prism gasket is even in the chambered area.
5. Place the new Teflon protective plate and steel plate over the prism and prism gasket and tighten the two M4 screws to a
torque of 4.5 Nm.
RELIANCE Omni Light
Maintenance
46
Copyright
©
ADB SAFEGATE, All Rights Reserved
Содержание RELIANCE
Страница 1: ...RELIANCE Omni Light 8 inch User Manual UM 5027 Rev 1 0 2020 12 10 ...
Страница 2: ......
Страница 8: ...RELIANCE Omni Light List of Figures viii Copyright ADB SAFEGATE All Rights Reserved ...
Страница 10: ...RELIANCE Omni Light List of Tables x Copyright ADB SAFEGATE All Rights Reserved ...
Страница 22: ...RELIANCE Omni Light General Information 12 Copyright ADB SAFEGATE All Rights Reserved ...
Страница 26: ...RELIANCE Omni Light Installation 16 Copyright ADB SAFEGATE All Rights Reserved ...
Страница 36: ...RELIANCE Omni Light Operation 26 Copyright ADB SAFEGATE All Rights Reserved ...
Страница 62: ...RELIANCE Omni Light Maintenance 52 Copyright ADB SAFEGATE All Rights Reserved ...
Страница 70: ...RELIANCE Omni Light POWER TABLE 60 Copyright ADB SAFEGATE All Rights Reserved ...
Страница 72: ...RELIANCE Omni Light CABLE LOSS 62 Copyright ADB SAFEGATE All Rights Reserved ...
Страница 76: ......