6.4.2 Opening a 8
‑
inch fixture
Removal
1. Place the light fixture upside down and remove the four screws for the bottom cover using an Allen key 4 mm.
Note
Refer to
figure.
2. Lift up the housing and disconnect the LED board cable connector from the LED boards in the top cover.
Note
Refer to Lifting
figure.
NOTICE
Open the light fixture carefully so that you do not damage the LED-board cables.
3. Remove the bottom cover from the top cover.
4. Remove the O-ring gasket from the bottom cover.
Note
Refer to
figure.
Figure 5: Fixture upside down
Figure 6: Lifting up housing
Figure 7: Removing gasket
6.4.3 Closing a 8
‑
inch fixture
Replacement
1. Carefully clean all contact surfaces of the light fixture and of the housing.
2. Install a new O-ring gasket on the bottom cover.
Important
The O-ring gasket must be changed each time the light fixture is disassembled.
3. Connect the LED board cable connector(s) to the supply terminal(s) of the converter in the housing.
NOTICE
Note the orientation and alignment of the LED board cables, which are different between 1 connector and 2
connector versions.
Converters with one connector: The cables should have colored wires towards each other and crossed.
Converters with two connectors: The cables should have colored wires away from each other and crossed.Light
fixtures with only one LED-board need to have its LED-board connected to the LED B channel.
UM-5027, Rev. 1.0, 2020/12/10
31
Copyright
©
ADB SAFEGATE, All Rights Reserved
Содержание RELIANCE
Страница 1: ...RELIANCE Omni Light 8 inch User Manual UM 5027 Rev 1 0 2020 12 10 ...
Страница 2: ......
Страница 8: ...RELIANCE Omni Light List of Figures viii Copyright ADB SAFEGATE All Rights Reserved ...
Страница 10: ...RELIANCE Omni Light List of Tables x Copyright ADB SAFEGATE All Rights Reserved ...
Страница 22: ...RELIANCE Omni Light General Information 12 Copyright ADB SAFEGATE All Rights Reserved ...
Страница 26: ...RELIANCE Omni Light Installation 16 Copyright ADB SAFEGATE All Rights Reserved ...
Страница 36: ...RELIANCE Omni Light Operation 26 Copyright ADB SAFEGATE All Rights Reserved ...
Страница 62: ...RELIANCE Omni Light Maintenance 52 Copyright ADB SAFEGATE All Rights Reserved ...
Страница 70: ...RELIANCE Omni Light POWER TABLE 60 Copyright ADB SAFEGATE All Rights Reserved ...
Страница 72: ...RELIANCE Omni Light CABLE LOSS 62 Copyright ADB SAFEGATE All Rights Reserved ...
Страница 76: ......