USER’S MANUAL
V-line 899x.xxx/LPG HYBRID
16
3
System VRC-M
+ VRMS
System VRC-M with automatic control system
– VRMS (Vapour Recovery
Monitoring System).
VRMS system independently monitors system VRC-M - detect faults in the
proper function recovery system Stage II petrol vapor and VRMS system
itself, indicate faults to the service station and automatically stops the
flow of petrol from the faulty dispenser (dispensing areas), if the fault is
not rectified within seven days.
4
System VRC-E
+ VRMS
System VRC-E with automatic control system
– VRMS (Vapour Recovery
Monitoring System).
VRMS system independently monitors system VRC-E - detect faults in the
proper function recovery system Stage II petrol vapor and VRMS system
itself, indicate faults to the service station and automatically stops the
flow of petrol from the faulty dispenser (dispensing areas), if the fault is
not rectified within seven days.
4.5.1.
Description of vapour recovery system
Pic.1
ADAST MINOR V-line 8991.623
ADAST POPULAR V-line 8991.423 ADAST POPULAR V-line 8995.423
Pos. 7 – vapour recovery system
4.5.2.
System VRC-M
Vapour Recovery Control – Mechanical - control the flow of vapor by hydromechanical proportional valve
integrated into nozzle (Elaflex GRVP).
Vapor recovery system VRC-M of the dispensers V-line 899x.xxx consists of the following basic
components (structural layout and design is evident from Figures 1, 2, 3, 4, 5):