USER’S MANUAL
V-line 899x.xxx/LPG HYBRID
36
IMPORTANT WARNING:
When filling the tank to 80% capacity cut off the mechanical limiter, and regardless of the manual
control button or switch.
In case the tank is filled to be full (most frequent case) the automatic safety level regulation
controlling the filling of the tank to 80 % max. shuts off the supply by means of a mechanical
limiter without respect to manual push-button control.
Při naplnění nádrže na 80 % objemu se uzavře přívod mechanickým omezovačem, a to bez ohledu
na ruční ovládání tlačítkem nebo přepínačem.
Non-dispensed preselected volume is reset after 20 seconds approximately.
9.
FUNCTIONS OF KL-MANINF MANAGER AND KL-SERINF SERVICE
KEYBOARDS
The KL-MANINF manager keyboard and the KL-SERINF service keyboard are delivered as a design with
infrared wireless transmission IR.
IR KL-MANINF manager keyboard
The keyboard enables the setting of unit prices and the situation display of electronic totalizers.
The manager keyboard is equipped with four keys marked „
0
―, „
+
―, „
–
― and „
R
―.
The „
0
― key is used for
the transition to the "setting of unit prices for MAN" and for the termination of any function executed on
the manager keyboard.
The „
+
― and „
–
― keys are used for proper setting of the unit price values or for the transition to the mode
of "situation display of electronic totalizers".
The „
R
― key is used for check of vapour recovery exhaustion.
IR KL-SERINF service keyboard
The keyboard enables the counter setting and the keying of values for electronic calibration of meters and
ATC, the situation display of electronic totalizers, setting of unit prices and setting the vapour exhaust
recovery.
The service keyboard is fitted with four keys, „
0
―, „
+
―„
–
― as a standard and the "
S
" key as an extra key.
The "
S
" key is used for the transition to the mode of "the data setting / calibration".
If the "
S
" key is not used, the service keyboard can be used for all functions controlled by the manager
keyboard and the keying is identical with that of the manager keyboard.
N. B.
If the nozzle has been lifted at least once since the last activation of the counter, the transition to the
setting of unit prices is not executed in the MAN mode. The transition to the setting is also not executed
even in case the nozzle has been either hung up again without fuel dispensing or previous transaction has
not been deactivated by means of RLS entry.
9.1.
Manual setting of unit prices
Necessary conditions for the transition to the setting of unit prices
– MAN mode of operation
– the nozzle has not been lifted since the last activation of the counter
– transaction executed shall be acknowledged (deactivation by means of RLS entries).
In the MAN mode the unit prices of fuel product are set by means of the KL-MANINF manager keyboard or
the KL-SERINF service keyboard.
1. The user can enter the setting mode of unit prices by depressing the „
0
― key.
2. In the setting mode of unit prices
–
the number of side for which the unit price is being set ("1" ... A side, "2" ... B side) is displayed on
the first line of displays (i.e. on the line of total price)
–
the number of nozzle for which the unit price is being set is displayed on the second line of
displays (i.e. the line of total volume)