10-4
Adaptec CI/O Management Software User’s Guide
5
Insert the replacement drive and issue the Rescan command.
6
If the array enclosure does not support hot swapping, pause
I/O to the array before you continue. (
Skip to Step 10 if the array
enclosure supports hot swapping.
) See
Pausing I/O on an Array
on
page 7-5.
Note:
Be sure to specify a Pause period that allows you
enough time to remove the failed drive or insert the
replacement drive. Wait a few seconds after issuing
the Pause I/O command before you remove or insert a
drive.
7
Remove the failed disk drive and allow I/O to resume.
8
Pause I/O again.
9
Insert the replacement drive and allow I/O to resume.
10
Select the icon of the new disk, and issue a Create Spare
command.
11
When a Pool spare with a capacity as large as the smallest
member of the critical array or a spare dedicated to the critical
array is created, the reconstruct will start automatically.
When the reconstruct is completed the array is in Fault-
tolerant status again, and the Array icon will look like this:
Replacing a Spare
Follow these steps to replace a spare drive that is recognized as good
by Adaptec CI/O Management Software:
1
Delete the spare. (See
Deleting a Spare
on page 5-17.)
1
Hot swapping
support means that the array enclosure electrically isolates the
bad disk’s SCSI connector from the SCSI bus while the disk is being
swapped to prevent data corruption. Data can still be transferred to and
from the remaining good disks while the bad drive is replaced.