6.3.4 Count pre-set or check-weighing
Check-weighing (or Count Pre-setting) is a procedure to cause an alarm to
sound when the net weight (or the number of items) on the scale meets or
exceeds a number stored in memory. The value to be stored is entered from the
keyboard.
SETTING OF PRESET LIMITS
It is possible to set a high and low limit for either counting or weighing (using net
weight). When the
[Pst]
key is pressed the user can select either counting or
weighing and then set the lower and upper limit.
For example:
ACTION DISPLAYS
Press
[Pst]
“PST ” “ nEt “ “ “
if currently in the weighing mode
Press
[U.Wt/Units]
“PST ” “ cnt “ “ “
to toggle from weighing to counting
Press
[Print]
“Hi cnt” “0.3 2 3 4” “ ”
The current high count limit is
displayed, press
[CE]
to clear and change if needed.
Press
[Print]
“lo cnt” “0.0 2 3 4” “ ”
The current low count limit is
displayed, press
[CE]
to clear and change if needed.
Press
[Print]
Return to weighing with limits set.
•
Clearing of either or both the limits is allowed. Both limits cleared will
disable the Preset altogether.
•
If Preset Weight was selected the first display would show “
Hi net
” and “
lo
net
”.
•
The beeper will work as described in the Beeper Parameter.