125
Model
Weighing Capacity
Readability (d)
Accuracy (e)
Tare Range (Subtractive)
Repeatability (std. deviation)
Linearity
Weighing Class
Response time (average)
Operating temperature range
Calibration
External cal. wt. (of at least accuracy class..)
Net Weight, approx.
Pan size
Weighing chamber height with draftshield
Weighing chamber height with Windshield
Dimensions (W x D x H) with draftshield
Dimensions (W x D x H) with windshield
DC power source / Power requirements
Frequency
Power consumption (average)
Selectable weight units
Built-in-interface
Format
Parity
Transmission rates :
Handshake mode
CY 123
120
0.001
0.01
-120
0.001
0.002
II
External
50 (F1)
CY 223
220
0.001
0.01
-220
0.001
0.002
II
15º to 30ºC
External
100 (F1)
CY 323
320
0.001
0.01
-320
0.001
0.002
II
15º to 30ºC
External
200 (F1)
CY 363
360
0.001
0.01
-360
0.001
0.002
II
15º to 30ºC
External
200 (F1)
CY 723
720
0.001
0.01
-720
0.002
0.003
I
18º to 30ºC
External
500 (F1)
CY 513
510
0.001
0.01
-510
0.002
0.003
II
15º to 30ºC
External
300 (F1)
CY 423
420
0.001
0.01
-420
0.001
0.002
II
15º to 30ºC
External
200 (F1)
2 - 3 sec.
15º to 30ºC
7.5kg
128 x 128
158.5
81
342.5 x 212 x 271
342.5 x 212 x 193.5
DC Adapter, input 100 ~ 240 0.8A output 13V / 1.5A
50 / 60Hz
maximum 18; typical 9
RS-232
1 start bit, 8-bit ASCII, parity, 1 or 2 stop bits
Mark, Space, Odd, even, none
300; 600; 1200; 2400; 4800; 9600; 19200; 57600 baud
None
gram, kilogram, pound, ounce, troy ounce, grain, pennyweight
carat, Milligram, momme, mesghal, Hong Kong tales, Singapore taels
Taiwan tales, baht
g
g
g
g
<=g
<=g
s
0
C
0
C
g
kg
mm
mm
mm
mm
mm
V~
Hz
VA
Precision Balances
CY 1003
1000
0.001
0.01
-1000
0.002
0.003
I
18º to 30ºC
External
500 (F1)
CY 363C
360
0.001
0.01
-360
0.001
0.002
II
15º to 30ºC
Internal
200 (F1)
126
Model
Weighing Capacity
Readability (d)
Accuracy (e)
Tare Range (Subtractive)
Repeatability (std. deviation)
Linearity
Weighing Class
Response time (average)
Operating temperature range
Calibration
External cal. wt. (of at least accuracy class..)
Net Weight, approx.
Pan size
Weighing chamber height with draftshield
Weighing chamber height with Windshield
Dimensions (W x D x H) with draftshield
Dimensions (W x D x H) with windshield
DC power source / Power requirements
Frequency
Power consumption (average)
Selectable weight units
Built-in-interface
Format
Parity
Transmission rates :
Handshake mode
CY 423C
420
0.001
0.01
-420
0.001
0.002
II
15º to 30ºC
Internal
200 (F1)
CY 513C
510
0.001
0.01
-510
0.002
0.003
II
15º to 30ºC
Internal
300 (F1)
CY 723C
720
0.001
0.01
-720
0.002
0.003
I
18º to 30ºC
Internal
500 (F1)
CY 323C
320
0.001
0.01
-320
0.001
0.002
II
15º to 30ºC
Internal
200 (F1)
CY 223C
220
0.001
0.01
-220
0.001
0.002
II
15º to 30ºC
Internal
100 (F1)
CY 123C
120
0.001
0.01
-120
0.001
0.002
II
Internal
50 (F1)
CY 1003C
1000
0.001
0.01
-1000
0.002
0.003
I
18º to 30ºC
Internal
500 (F1)
2 - 3 sec.
15º to 30ºC
7.8kg
128 x 128
158.5
81
342.5 x 212 x 271
342.5 x 212 x 193.5
DC Adapter, input 100 ~ 240 0.8A output 13V / 1.5A
50 / 60Hz
maximum 18; typical 9
RS-232
1 start bit, 8-bit ASCII, parity, 1 or 2 stop bits
Mark, Space, Odd, even, none
300; 600; 1200; 2400; 4800; 9600; 19200; 57600 baud
None
gram, kilogram, pound, ounce, troy ounce, grain, pennyweight
carat, Milligram, momme, mesghal, Hong Kong tales, Singapore taels
Taiwan tales, baht
g
g
g
g
<=g
<=g
s
0
C
0
C
g
kg
mm
mm
mm
mm
mm
V~
Hz
VA
Precision Balances