Scope_manual_en-v110.docx
— 43 —
Fig. 100
– Multi-Diag Scope in the diode test mode (figure applies to version 7.2.4)
14.6
MEASUREMENT ON THE HV COIL
– SECONDARY WINDING (SINCE SW VERSION – 11.0)
The measuring is carried out by means of HV sensors that are connected to HV cables or to the ignition module.
Types of high-voltage sensor and their use in oscilloscope
– see Chap. I - 14.6.1 and Chap. I - 14.6.4
14.6.1
HV SENSOR N (AT111 4018) + HV REFERENCE CABLE (AT 111 4056)
Option for Multi-Diag Scope
HV probe N
is used for measuring of the high voltage on the spark
plugs by fitting the vehicle HV cable
– see Fig. 101.
During measuring on HV cables, when is required measuring of
flashover voltage, is necessary insert the
High-voltage reference
cable
between ignition cable and spark plug. At this
HV Reference
cable
then put
HV probe N
– see Fig. 102
Ground High
Voltage probe N
High Voltage
probe N
High Voltage
cable
Ground High
Voltage probe N
High Voltage
probe N
High Voltage
Reference cable
High Voltage
cable
Fig. 101
– Measurement of high voltage on one cylinder with a
high voltage cables with HV probe N
Fig. 102
– Measurement of high voltage on one cylinder with a
high voltage cables with HV probe N and HV Reference cable