Gen II
User Manual
17-2 – Monitor Magnitude & Clock
Chapter 17
Revision 2.01, Apr 2020
From the Main Menu banner screen, select “Monitor Magnitude and Clock.” The
“Monitor Magnitude and Clock” banner screen appears as shown in the figure below.
Use the [
] key to toggle between the selections in the “Tach Channel” field. Toggle
between selections using the [
] keys to select the tachometer-input channel to be
monitored.
Move down to the “Tach Type” field by using the [
] key. Use the [
] key to select the
tachometer type you are using for the once-per-revolution input into the analyzer.
Use the [
] key to move to the “Vibration” field. The “Vibration” field determines the
engineering units in which the amplitude, or “Y” axis, of the spectra will be displayed.
Consult the appropriate equipment maintenance manual for specific requirements of a
vibration survey or for analysis guidelines. Use the [
] or [
] keys to scroll through the
selections in this field. The available selections are: IPS (Inches Per Second), mm/sec
(millimeters per second), cm/sec (centimeters per second), mils (1/1000th of an inch),
microns (1/1000000th of a meter), m/s/s (meters per second squared), and cm/s/s
(centimeters per second squared).
Use the [
] key to move to the “Modifier” field. “Mod” is short for unit Modifiers
relevant to the vibration engineering units specified above. Use the [
] or [
] keys to
toggle through the available selections in the field which are: Peak, Pk-Pk (Peak to Peak),
Avg. (Average), and RMS (Root Mean Square). Consult the appropriate equipment
maintenance manual for specific requirements of a vibration survey or for analysis
guidelines.
Use the [
] key to move to the “Tach Filter Type” field. Use the [
] or [
] keys to
toggle through the available selections in the field which are: “Single” pole filter,
“Double” pole filter or “None”.
Use the [
] key to move to the “Tach Filter Freq” field. Use the Keypad to enter a
numeric value equal to the lowest frequency of interest. The filter will then be effective
for that frequency and all frequencies above that value.