24
2.4.
Operating data
Production of domestic hot water with ∆T of 30 °C = 12 l / min
Production of domestic hot water with ∆T of 25 °C = 15 l / min
Play 24
Function
Thermal range
heating
[kW]
Thermal power
heating
(80-60°C)
[kW]
Thermal power
heating
(50-30°C)
[kW]
Supply
pressure
[mbar]
[mm]
Val
ue
CO
2
of the fumes
[%]
min
max
min
max
min
max
min
max
Natural gas G20
2,8
24,0
2,5
23,0
2,9
24,9
20
5,6
9,3
9,8
LPG gas
2,8
24,0
2,5
23,0
2,9
24,9
30/37
5,6
10,4
10,7
Table 6 - Play 24 calibration data
Production of domestic hot water with ∆T of 45 °C = 8.6 l / min
Production of domestic hot water with ∆T of 40 °C = 9.6 l / min
Production of domestic hot water with ∆T of 35 °C = 11 l / min
Production of domestic hot water with ∆T of 30 °C = 13.3 l / min
Production of domestic hot water with ∆T of 25 °C = 16.0 l / min
Function
Thermal range
heating
[kW]
Thermal power
heating
(80-60°C)
[kW]
Thermal power
heating
(50-30°C)
[kW]
Supply
pressure
[mbar]
Diameter
diaphragm
[mm]
Value
CO
2
of the fumes
[%]
min
max
min
max
min
max
min
max
Natural gas G20
3,1
28,0
2,9
26,9
3,2
29,2
20
6,0
9,0
9,0
LPG gas
3,1
28,0
2,9
26,9
3,2
29,2
30/37
6,0
10,5
10,5
Table 8 - Play 28 calibration data
Production of domestic hot water with ∆T of 45 °C = 8.9 l / min
Production of domestic hot water with ∆T of 40 °C = 10.0 l / min
Production of domestic hot water with ∆T of 35 °C = 11.4 l / min
2.5.
General features*
MODEL Play
24
28
32
Appliance category
-
II2H3P
II2H3P
II2H3P
Minimum heating circuit pressure
bar
0,5
0,5
0,5
Maximum pressure of the heating circuit
bar
3
3
3
Minimum pressure of the sanitary circuit
bar
0,5
0,5
0,5
Maximum pressure of the sanitary circuit
bar
6
6
6
Specific flow rate of sanitary water
∆T 30K)
l/min
12
13,3
14
Power supply - Voltage / Frequency
V - Hz
230 - 50
230 - 50
230 - 50
Power supply fuse
A
3,15
3,15
3,15
Maximum absorbed power
W
87
87
102
Degree of electrical protection
IP
X4D
X4D
X4D
Net weight
kg
29,9
31,4
33,0
Net weight
kg
29,4
30,8
32,4
Methane gas consumption at the maximum flow rate in heating. (*)
m
3
/h
2,54
2,90
3,37
LPG consumption at the maximum flow rate in heating. (*)
m
3
/h
0,75
0,83
0,97
Fan speed G20 heating max / min. (x100)
rpm
48 / 9
55 / 9
52 / 11
Max DHW G20 fan speed (x100)
rpm
62,5
65,25
62,5
LPG heating fan rpm max / min. (x100)
rpm
54 / 9
49 / 9
53 / 9
Number of DHW LPG fan revolutions max (x100)
rpm
64,5
57
59,5
Fan speed G20 ignition (x100)
rpm
35
35
35
Ignition LPG fan rpm (x100)
rpm
32
32
32
Max operating temperature in heating
°C
85
85
85
Max operating temperature in domestic hot water
°C
60
60
60
Total expansion vessel capacity
l
9
9
9
TTable 12 - Play general data
Production of domestic hot water with ∆T of 30 °C = 14 l / min
Production of domestic hot water with ∆T of 25 °C = 19
Function
Thermal range
heating
[kW]
Thermal power
heating
(80-60°C)
[kW]
Thermal power
heating
(50-30°C)
[kW]
Supply
pressure
[mbar]
Diameter
diaphragm
[mm]
Value
CO
2
of the fumes
[%]
min
max
min
max
min
max
min
max
Natural gas G20
3,4
32,0
3,3
30,8
3,5
33,5
20
6,3
8,4
10,6
LPG gas
3,4
32,0
3,3
30,8
3,5
33,5
30/37
6,3
10,5
10,6
Table 10 - Play 32 calibration data
Production of domestic hot water with ∆T of 45 °C = 10.5 l / min
Production of domestic hot water with ∆T of 40 °C = 11.9 l / min
Production of domestic hot water with ∆T of 35 °C = 13.6 l / min
Play 28
Play 32
The burner pressures shown on the following page must be checked after 3 minutes of boiler operation.
Diameter
diaphragm
Содержание PLAY 24
Страница 45: ...45 3 6 3 Wiring diagram fig 21...
Страница 52: ......
Страница 53: ......
Страница 55: ...2...