background image

addendum instructions

for solar appliance

please leaVe tHese instructions in tHe pocket proVided on 

tHe back of tHe front panel

a sealed sYstem central Heating and mains 

pressure Hot water supplY appliance witH 

tHermal store designed specificallY for use 

witH solar energY

tHese instructions must be read in 

conjunction witH tHe standard 

boilermate a-class sp 

design, installation and serVicing 

instructions before installation

TM

benchmark

The code of practice for the installation,

commissioning & servicing of central heating systems

models

BMA 200 SP - SOL  
BMA 220 SP - SOL  
BMA 240 SP - SOL   

    

 

Boiler

Mate SP SOL

A - C L A S S

Содержание BMA 200 SP

Страница 1: ...ance with thermal store designed specifically for use with solar energy these instructions must be read in conjunction with the standard boilermate a class sP design installation and servicing instructions before installation TM benchmark Thecodeofpracticefortheinstallation commissioning servicingofcentralheatingsystems Models BMA 200 SP SOL BMA 220 SP SOL BMA 240 SP SOL BoilerMate SP SOL A C L A ...

Страница 2: ... 06 CORGI operates a Self Certification Scheme for gas heating appliances These arrangements represent a change from the situation whereby compliance with the Building Regulations was accepted if the Benchmark Logbook was completed and this was then left on site with the customer With the introduction of a self certification scheme the Benchmark Logbook is being replaced by a similar document in t...

Страница 3: ...1 2 2 En Suite 2 1 2 Weight Empty kg 79 Full kg 260 SensorT3providesahightemperatureinterlock to de activate the solar pump at a temperature of 90ºC in the store Although sensorsT1 andT2 are wired in to the solar controller the cable provided for Sensor T1 3 metres long may require to be extended by the installer dependant on the location of the solar panels appliance 2 x 0 75mm2 double insulated ...

Страница 4: ...r opening if door is located directly in front of the appliance Maintenance access Increase to 350mm to provide the minimum maintenance access to comply with the Water Regulations if a ballvalve and overflow are being fitted F C 300mm 420mm 280mm 600mm 100mm 250mm D A F E Cistern F E Cistern BoilerMate A Class Solar Appliance Dimensions Model Height A Width B Depth C BMA 200 SP SOL 1330 560 620 BM...

Страница 5: ...16 HW outlet 17 Drain tapping 18 Return from PHE to store 19 Flow from store to PHE 1 2 technical data 20 Boiler Return 21 C H Return 22 Boiler flow 23 CH flow 24 Towel rail connection 15mm all models 25 Solar heat exchanger return to solar panel 26 Solar heat exchanger flow collector from panel 27 Bottom solar sensor pocket 28 Top solar overheat thermostat pockets 29 3 port valve mid position 30 ...

Страница 6: ...W Pump Boiler Pump SOLAR CONTROLLER DANFOSS SH E01 Solar circuit Pump N L T1 COM T2 AL P1 T2 Temperature sensor in Boilermate Solar Zone pocket N Solar Pump High Store temperature interlock Capillary Thermostat set to 85 C Cotherm GTLH0054 o SOLAR CONTROLLER SUPPLY T1 Temperature sensor at Solar panel collector this must be fitted and wired by the installer The cable must be 0 75mm two core double...

Страница 7: ... setting of Channel 1 and the operation of the summer winter rocker switch are provided on the labels adjacent to the controls Channel 2 should be set as normal to control the heating on off times required If a high hot water demand is expected or the appliance runs out of hot water the setting of Channel 1 can be overridden which will bring on the boiler and ensure hot water is made available The...

Страница 8: ... service AUTO MAN STOP Temperature in hot water thermal store Temperature in solar collector The solar heat circuit circulation pump is controlled by the differential temperature between the solar collector and the store bottom If the differential temperature is higher than the preset start up temperature differential the circulation pump will run To avoid unnecessary pump operation the temperatur...

Страница 9: ...been cooled to 60ºC The pump must be on AUTO Temperature indication Solar collector Thermal Store 0 95 120 40 Operating range Sensor fault alarm Sensor fault alarm Sensor fault alarm High temp alarm Low temp Low temp Display 0 C flashes F2 flashes Meaning 99 Temp flashes F2 flashes 99 C flashes C 0 120 150 200 9 40 Operating range Sensor fault alarm High temp Display 150 C flashes Temp flashes Tem...

Страница 10: ...ns and all relevant codes of practice and regulations in force at the time of installation That all necessary inlet controls and safety valves have been fitted correctly It has only been used for the storage of potable water supplied from the public mains Where appropriate the unit has been regularly maintained as detailed in the installation and service instructions 1 Domestic and Commercial Open...

Страница 11: ...ssociated with a fiduciary relationship shall apply d the Purchaser s right to possess the goods shall cease forthwith upon the happening of any of the following events namely i if the Purchaser fails to make payment in full for the goods within the time stipulated in clause 4 hereof ii if the Purchaser not being a company commits any act of bankruptcy makes a proposal to his or her creditors for ...

Страница 12: ......

Отзывы: