Error and tamper monitoring
The hybrid module continually monitors error and tamper states and reports all events to the alarm
panel. The following is monitored:
•
Tamper contact:
The hybrid module’s tamper contact is continually monitored.
•
Supply voltage:
The hybrid module monitors the supply voltage under load conditions and reports faults to
the alarm panel.
•
Supervision
The hybrid module continually sends supervision messages to the alarm panel
•
Signal jamming:
The hybrid module monitors attempts to jam the wireless signal
.
If jamming is detected, the
message “Signal jamming” is sent to the alarm panel.
•
Load on the voltage outputs.
Danger
The self-repairing fuse will react in the event of excessive currents.
Check the power consumption and whether the consumer is properly con-
nected.
Time conditions
The hybrid module was designed so that changes to the zone status are detected if they last at
least 400 ms (EN50131-1 Chapter 8.9.1 and EN50131-3 Chapter 8.9 and Annex B).
Break-in, intrusion and tampering signals must last at least 400 ms.
The hybrid module was designed so that changes to the fault status (fault signals) are detected if
they last at least 10 s (EN50131-1 Chapter 8.9.1 and EN50131-3 Chapter 8.9 and Annex B).
Factory Defaults
If the hybrid module is paired with the alarm panel again, it discards all previous links. This causes
the hybrid module to return to the factory default.
Содержание FUMO50110
Страница 13: ...Funktionsprinzip und Leistungsmerkmale 13 D E Ger tebeschreibung Bild 1...
Страница 24: ...Montage 24 D E Anschluss Sirene Bild 9...
Страница 27: ...Montage 27 D E Anschluss wAppLoxx Control Bild 10...
Страница 57: ...Functional principle and features 57 EN Device description Image 1...
Страница 68: ...Installation 68 EN Sounder connection Image 9...
Страница 71: ...Installation 71 EN wAppLoxx Control connection Image 10...
Страница 101: ...Principe de fonctionnement et caract ristiques 101 FR Description de l appareil Figure 1...
Страница 110: ...Montage 110 FR Exemple pour 2 fils FSL 2k2 4k7 Figure 6 Variante 4 fils 4 fils NC Exemple pour 4 fils NC Figure 7...
Страница 112: ...Montage 112 FR Raccordement sir ne Figure 9...
Страница 115: ...Montage 115 FR Raccordement wAppLoxx Control Figure 10...
Страница 118: ...Montage 118 FR...
Страница 122: ...Montage 122 FR...
Страница 147: ...Werkingsprincipe en eigenschappen 147 NL Beschrijving van het apparaat Afbeelding 1...
Страница 158: ...Montage 158 NL Aansluiting sirene Afbeelding 9...
Страница 161: ...Montage 161 NL Aansluiting wAppLoxx Control Afbeelding 10...
Страница 191: ...Funktionsprincip og funktioner 191 DA Beskrivelse af udstyret Ill 1...
Страница 200: ...Montering 200 DA Eksempel p en 2 tr det FSL 2k2 4k7 Ill 6 Variant 4 tr det 4 tr det CC Eksempel p 4 tr det CC Ill 7...
Страница 202: ...Montering 202 DA Tilslutning sirene Ill 9...
Страница 205: ...Montering 205 DA Tilslutning wAppLoxx Control Pro Ill 10...
Страница 235: ...Principio di funzionamento e caratteristiche 235 IT Descrizione dell apparecchio Figura 1...
Страница 246: ...Fehler Kein Text mit angegebener Formatvorlage im Dokument 246 IT Porta sirena Figura 9...
Страница 249: ...Montaggio 249 IT Collegamento wAppLoxx Control Figura 10...
Страница 255: ...Montaggio 255 IT...