BAL.0361.0 • 2017-05-05
EN - 19
iCAT mini
7 Operation
4
Shorten the wire guide on the front side by dimension a
Shorten it so that it is slightly tight after installation.
5
Insert the wire guide in the cable assembly until it reaches the stop and
secure with set screw M4 × 5
.
7 Operation
Since the
iCAT mini
is integrated in the torch’s welding process, the operating
steps are performed after the respective torch and the welding power source
has been put into operation. Observe the operating instructions of the relevant
welding torch.
8 Decommissioning
Decommissioning depends on the respective welding torch. Observe the
operating instructions of the relevant welding torch and welding power source.
9 Maintenance and cleaning
Scheduled maintenance and cleaning are prerequisites for a long service life
and trouble-free operation.
DANGER
Risk of injury due to unexpected start
The following instructions must be followed during all maintenance,
servicing, assembly, disassembly, and repair work:
• Switch off the power source.
• Close off the gas supply.
• Close the compressed air supply.
• Disconnect all electrical connections.
• Switch off the entire welding system.
DANGER
Electric shock
Dangerous voltage due to defective cables.
• Check all live cables and connections for proper installation and
damage.
• Replace any damaged, deformed or worn parts.
Содержание iCAT mini ABIROB G
Страница 4: ...DE 4 BAL 0361 0 2017 05 05 1 Identifikation iCAT mini 1 1 EU Konformitätserklärung ...
Страница 28: ...EN 4 BAL 0361 0 2017 05 05 1 Identification iCAT mini 1 1 EU Declaration of Conformity ...
Страница 52: ...ZH 4 BAL 0361 0 2017 05 05 1 识别 iCAT mini 1 1 欧盟符合性声明 ...
Страница 76: ...JA 4 BAL 0361 0 2017 05 05 1 概要 iCAT mini 1 1 EU適合宣言 ...