BAL.0361.0 • 2017-05-05
EN - 23
iCAT mini
11 Disassembly
11 Disassembly
D
Welding wire is not
correctly fed
• Wire conduit coil is soiled
• Disassemble wire conduit coil
and air-blast with compressed air
• Wear safety goggles
9 Maintenance and cleaning
on page EN-19
• Wire conduit coil worn
• Replace wire conduit coil
• Wire conduit coil cut to short
• Mount new wire conduit coil
• Wire guide soiled by wire wear
(model with wire brake)
• Disassemble wire guide and air-
blast with compressed air.
• Wear safety goggles
9 Maintenance and cleaning
on page EN-19
Fault
Cause
Troubleshooting
Tab. 11
Troubleshooting
DANGER
Risk of injury due to unexpected start
The following instructions must be followed during all maintenance,
servicing, disassembly and repair work:
• Switch off the power source.
• Close off the gas supply.
• Close the compressed air supply.
• Disconnect all electrical connections.
• Switch off the entire welding system.
DANGER
Electric shock
Dangerous voltage due to defective cables.
• Check all live cables and connections for proper installation and
damage.
• Replace any damaged, deformed or worn parts.
Содержание iCAT mini ABIROB G
Страница 4: ...DE 4 BAL 0361 0 2017 05 05 1 Identifikation iCAT mini 1 1 EU Konformitätserklärung ...
Страница 28: ...EN 4 BAL 0361 0 2017 05 05 1 Identification iCAT mini 1 1 EU Declaration of Conformity ...
Страница 52: ...ZH 4 BAL 0361 0 2017 05 05 1 识别 iCAT mini 1 1 欧盟符合性声明 ...
Страница 76: ...JA 4 BAL 0361 0 2017 05 05 1 概要 iCAT mini 1 1 EU適合宣言 ...